Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode

Yükleniyor...
Küçük Resim

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Wiley-VCH Verlag

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Herein, a new strategy for the fabrication of a sensitive immunosensor capable of determination of CC Chemokine receptor 4 (CCR4) in complex serum samples is developed through the polymer modification on the disposable indium tin oxide electrode. Anti-CCR4 antibodies, which are utilized as sensing biomolecules, are covalently attached on the succinimide groups of polypyrrole polymer (PPyr-CSsg). The constructed immunosensor illustrates promising performances for the quantification of CCR4 antigen, with a linear detection range of 0.024–12 pg mL−1 and a low detection limit of 7.3 fg mL−1, calculated at a signal-to-noise ratio of 3. In addition, the impedimetric immunosensor displays a very successful analytical performance in terms of sensitivity, selectivity, repeatability, reproducibility, and long-term stability as well as successful applicability for the accurate quantification of CCR4 in human serum samples. The constructed immunosensor is successfully used for quantification of CCR4 antigen in human serums. In addition, the immunosensor displays only 27.54% loss in its initial signal after nine weeks storage at 4 °C. Moreover, the fabricated immunosensor is economical, highly sensitive, and selective for CCR4 antigen detection, and suitable for potential application in clinical diagnosis.

Açıklama

Anahtar Kelimeler

CC Chemokine receptor 4, Electrochemical impedance spectroscopy, Immunosensor, Polypyrrole polymer containing succinimide groups

Kaynak

Macromolecular Bioscience

WoS Q Değeri

Q2

Scopus Q Değeri

Cilt

21

Sayı

2

Künye

Aydın, E. B., Aydın, M., & Sezgintürk, M. K. (2021). Electrochemical Immunosensor for Detection of CCR4 Cancer Biomarker in Human Serum: An Alternative Strategy for Modification of Disposable ITO Electrode. Macromolecular bioscience, 21(2), e2000267. https://doi.org/10.1002/mabi.202000267