Effectiveness of fly ash in boron removal from Tuzla (Çanakkale) geothermal fluid

dc.authorid0000-0002-4453-6187en_US
dc.authorid0000-0001-9180-3623en_US
dc.authorid0000-0001-6546-5624en_US
dc.authorscopusid58026002000en_US
dc.authorscopusid57062703100en_US
dc.authorscopusid56430749600en_US
dc.authorwosid-en_US
dc.authorwosidJVZ-7405-2024en_US
dc.authorwosid-en_US
dc.contributor.authorŞahin, Mehmet Oğuzhan
dc.contributor.authorBektaş, Tijen Ennil
dc.contributor.authorŞanlıyüksel Yücel, Deniz
dc.date.accessioned2025-02-07T13:45:28Z
dc.date.available2025-02-07T13:45:28Z
dc.date.issued2021en_US
dc.departmentEnstitüler, Lisansüstü Eğitim Enstitüsü, Enerji Kaynakları ve Yönetimi Ana Bilim Dalıen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Kimya Mühendisliği Bölümüen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Maden Mühendisliği Bölümüen_US
dc.descriptionThis paper has been presented at EurAsia Waste Management Symposium 2020, Istanbul, Turkey.
dc.description.abstractThe heat accumulated in the inner parts of the earth's crust is transmitted to the fluid in the geothermal aquifer by means of transportation. The geothermal fluid is transported to the surface either by wells or naturally. In this study, the geothermal fluid in Tuzla geothermal field in Çanakkale city was examined due to its high boron content (10.3 mg L-1). It was aimed to remove boron from geothermal fluid by adsorption in order to prevent possible negative effects on the environment. Fly ash was obtained from Çan thermal power plant. The specific surface area of the fly ash was 14.6 m2 g-1 and the particle size was between 1.45 and 186 µm. According to ASTM C618 standard, fly ash was classified as Class C. Fly ash was composed of anhydrite, lime, hematite, cristobalite, quartz, calcite and feldspar. Various parameters such as initial pH, adsorbent dosage, contact time, and temperature were studied experimentally for the removal of boron from the geothermal fluid. The suitability of pseudo-first-order, pseudo-second-order, and intraparticle kinetic models to experimental data was examined. The data obtained from the isotherm studies were applied to the Langmuir, Freundlich and Dubinin-Radushkevich models.
dc.identifier.citationŞahin, M. O., Bektaş, T. E., & Şanlıyüksel Yücel, D. (2021). Effectiveness of fly ash in boron removal from Tuzla (Çanakkale) geothermal fluid. Environmental Research and Technology, 4(1), 102-107. https://doi.org/10.35208/ert.842192en_US
dc.identifier.doi10.35208/ert.842192en_US
dc.identifier.endpage107en_US
dc.identifier.issn2636-8498
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85132896554en_US
dc.identifier.scopusqualityQ4
dc.identifier.startpage102en_US
dc.identifier.trdizinid433296en_US
dc.identifier.urihttps://doi.org/10.35208/ert.842192
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/433296
dc.identifier.urihttps://hdl.handle.net/20.500.12428/29587
dc.identifier.volume4en_US
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorŞahin, Mehmet Oğuzhan
dc.institutionauthorBektaş, Tijen Ennil
dc.institutionauthorŞanlıyüksel Yücel, Deniz
dc.institutionauthorid0000-0002-4453-6187
dc.institutionauthorid0000-0001-9180-3623
dc.institutionauthorid0000-0001-6546-5624
dc.language.isoengen_US
dc.publisherYıldız Technical Universityen_US
dc.relation.ispartofEnvironmental Research and Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdsorptionen_US
dc.subjectBoronen_US
dc.subjectFly ashen_US
dc.subjectGeothermal fluiden_US
dc.titleEffectiveness of fly ash in boron removal from Tuzla (Çanakkale) geothermal fluiden_US
dc.typearticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tijen Ennil Bektas_Makale.pdf
Boyut:
1.22 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Araştırma Makalesi
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.21 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: