Sensitive Electrochemical Determination of Trifluralin at a Disposable Pencil Graphite Electrode

dc.authorid0000-0001-8309-7116en_US
dc.authorid0000-0002-6401-3295en_US
dc.authorid0000-0002-2980-6871en_US
dc.authorscopusid57222534885en_US
dc.authorscopusid56374132900en_US
dc.authorscopusid6507953466en_US
dc.authorwosidCRT-2210-2022en_US
dc.authorwosidCXU-1963-2022en_US
dc.authorwosidDTM-7891-2022en_US
dc.contributor.authorGege, Ümit
dc.contributor.authorKarakaya, Serkan
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2022-08-11T13:49:46Z
dc.date.available2022-08-11T13:49:46Z
dc.date.issued2021en_US
dc.departmentEnstitüler, Lisansüstü Eğitim Enstitüsü, Kimya Ana Bilim Dalı
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümü
dc.description.abstractA sensitive differential pulse (DP) voltammetric method has been proposed for the determination of trifluralin (TFA) based on both its reduction and oxidation at a disposable pencil graphite electrode (PGE). DP voltammograms recorded under optimized conditions show that oxidation and reduction peak currents increased linearly in the range from 1.0 to 75.0 mu M and from 0.50 to 100.0 mu M TFA, respectively. LOD and sensitivity values have been determined as 0.39 mu M and 11170 mu A mM(-1) cm(-2) for oxidation and as 0.20 mu M and 22167 mu A mM(-1) cm(-2) for reduction. The acceptable recovery values (95.2-104.8 %) were obtained from real water samples.en_US
dc.identifier.citationGege, Ü., Karakaya, S., & Dilgin, Y. (2021). Sensitive Electrochemical Determination of Trifluralin at a Disposable Pencil Graphite Electrode. Electroanalysis, 33(6), 1547–1556. https://doi.org/10.1002/elan.202060618 ‌en_US
dc.identifier.doi10.1002/elan.202060618
dc.identifier.endpage1556en_US
dc.identifier.issn1040-0397
dc.identifier.issn1521-4109
dc.identifier.issue6en_US
dc.identifier.scopus2-s2.0-85103133538
dc.identifier.startpage1547en_US
dc.identifier.urihttps://doi.org/10.1002/elan.202060618
dc.identifier.urihttps://hdl.handle.net/20.500.12428/3669
dc.identifier.volume33en_US
dc.identifier.wosWOS:000631125700001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorGege, Ümit
dc.institutionauthorKarakaya, Serkan
dc.institutionauthorDilgin, Yusuf
dc.language.isoen
dc.publisherWileyen_US
dc.relation.ispartofElectroanalysisen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDifferential Pulse Voltammetryen_US
dc.subjectElectrochemical Sensoren_US
dc.subjectPencil Graphite Electrodeen_US
dc.subjectPesticideTrifluralinen_US
dc.titleSensitive Electrochemical Determination of Trifluralin at a Disposable Pencil Graphite Electrode
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Umit_Gege_Makale.pdf
Boyut:
1.67 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Araştırma Makalesi
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: