Effect of Using High-Speed Drill in Anterior Cervical Discectomy and Fusion

dc.authoridAras, Adem Bozkurt/0000-0002-0140-5224
dc.contributor.authorGuven, Mustafa
dc.contributor.authorCeylan, Davut
dc.contributor.authorAras, Adem Bozkurt
dc.contributor.authorAkbal, Ayla
dc.contributor.authorGokmen, Ferhat
dc.contributor.authorResorlu, Hatice
dc.contributor.authorAlkan, Bahadir
dc.date.accessioned2025-01-27T20:52:07Z
dc.date.available2025-01-27T20:52:07Z
dc.date.issued2016
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractAIM: The objective of this study was to investigate the effect of using 2 different surgical techniques (curette or high-speed drill) in anterior cervical discectomy surgery on the healing of cases. MATERIAL and METHODS: Fifty-four operated cervical disc hernia cases were retrospectively examined in 2 groups. Discectomy and osteophytectomy were carried out in Group A by using a high-speed drill, while a curette was used for group B. Preoperative and postoperative computerized tomography and direct radiography were performed. Cervical disc height, cervical and segmental lordotic angles were calculated. The visual analogue scale and Odom's criteria were used in the assessment of pain and clinical healing. The fusion ratio of both groups was compared. The Mann-Whitney U test was used to compare data from the groups. RESULTS: Satisfactory results were obtained in the groups where high-speed drill and curette were used. Independently from the surgical technique, pain scores were significantly reduced in both groups after surgery. No radiologically significant differences were identified between the two groups within the postoperative period. CONCLUSION: Either high-speed drill or curette can be chosen for the osteophytectomy and discectomy stages of anterior cervical discectomy operations.
dc.identifier.doi10.5137/1019-5149.JTN.11182-14.2
dc.identifier.endpage104
dc.identifier.issn1019-5149
dc.identifier.issue1
dc.identifier.pmid26768875
dc.identifier.scopus2-s2.0-84959516846
dc.identifier.scopusqualityQ3
dc.identifier.startpage97
dc.identifier.trdizinid210329
dc.identifier.urihttps://doi.org/10.5137/1019-5149.JTN.11182-14.2
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/210329
dc.identifier.urihttps://hdl.handle.net/20.500.12428/25667
dc.identifier.volume26
dc.identifier.wosWOS:000372668500014
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherTurkish Neurosurgical Soc
dc.relation.ispartofTurkish Neurosurgery
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20250125
dc.subjectCervical
dc.subjectDiscectomy
dc.subjectFusion
dc.subjectCurette
dc.subjectHigh-speed drill
dc.subjectEndplate
dc.titleEffect of Using High-Speed Drill in Anterior Cervical Discectomy and Fusion