Photoelectrocatalytic determination of NADH in a flow injection system with electropolymerized methylene blue
dc.authorid | Dilgin, Yusuf/0000-0002-2980-6871 | |
dc.authorid | Giray Dilgin, Didem/0000-0002-3487-3470 | |
dc.contributor.author | Dilgin, Yusuf | |
dc.contributor.author | Dilgin, Didem Giray | |
dc.contributor.author | Dursun, Zekerya | |
dc.contributor.author | Gokcel, H. Ismet | |
dc.contributor.author | Gligor, Delia | |
dc.contributor.author | Bayrak, Burcu | |
dc.contributor.author | Ertek, Bensu | |
dc.date.accessioned | 2025-01-27T20:27:21Z | |
dc.date.available | 2025-01-27T20:27:21Z | |
dc.date.issued | 2011 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | It was firstly described that a glassy carbon electrode electropolymerized with methylene blue shows an efficient photoelectrocatalytic activity towards NADH oxidation in a phosphate buffer solution (pH 7.0). In order to perform the photoelectrocatalytic determination of NADH in a flow injection analysis (FIA) system, a home-made flow electrochemical cell with a suitable transparent window for the irradiation of the electrode surface was constructed. The currents obtained from the photoamperometric measurements in the FIA system at optimum conditions (flow rate of carrier solution, 1.3 mL min(-1): transmission tubing length, 10 cm; injection volume, 100 mu L; and constant applied potential, +150 mV vs. Ag/AgCl) were linearly dependent on the NADH concentration and linear calibration curves were obtained in the range of 1.0 x 10(-7)-2.0 x 10(-4) M. The detection limit was found to be 4.0 x 10(-8) M for photoamperometric determination of NADH. (C) 2010 Elsevier Ltd. All rights reserved. | |
dc.description.sponsorship | Scientific and Technological Research Council of Turkey TUBITAK [107T572]; National Authority for Scientific Research of Romania ANCS [75CB/18.07.2008]; Canakkale Onsekiz Mart University [COMU BAP 2009/15] | |
dc.description.sponsorship | The authors acknowledge the Scientific and Technological Research Council of Turkey TUBITAK (Project No. 107T572) and the National Authority for Scientific Research of Romania ANCS (Project No. 75CB/18.07.2008) for financial support. Y. Dilgin, B. Bayrak and B. Ertek would like to thank Canakkale Onsekiz Mart University Scientific Research Project Commission Fund for partially supporting of this work with a project (COMU BAP 2009/15). | |
dc.identifier.doi | 10.1016/j.electacta.2010.10.084 | |
dc.identifier.endpage | 1143 | |
dc.identifier.issn | 0013-4686 | |
dc.identifier.issn | 1873-3859 | |
dc.identifier.issue | 3 | |
dc.identifier.scopus | 2-s2.0-78650509786 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 1138 | |
dc.identifier.uri | https://doi.org/10.1016/j.electacta.2010.10.084 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/22663 | |
dc.identifier.volume | 56 | |
dc.identifier.wos | WOS:000289225400019 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Pergamon-Elsevier Science Ltd | |
dc.relation.ispartof | Electrochimica Acta | |
dc.relation.publicationcategory | info:eu-repo/semantics/openAccess | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_WoS_20250125 | |
dc.subject | Photoelectrocatalysis | |
dc.subject | Flow injection analysis | |
dc.subject | Modified electrode | |
dc.subject | NADH | |
dc.subject | Methylene blue | |
dc.title | Photoelectrocatalytic determination of NADH in a flow injection system with electropolymerized methylene blue | |
dc.type | Article |