dc.description.abstractBackground: One of the most important reasons for nasal congestion is septum deviation. Nasal septal deviation increases airway resistance and can cause systemic problems. In this study, echocardiographic findings were compared with the normal population to see how cardiac function was affected in patients with obstructive nasal septum deviation. Methods: This study included a young patient group with 44 obstructive septum deviation patients and 30 healthy individuals with no nasal-related problems. Echocardiography was performed by the same cardiologist and results were compared with normal patients. The authors got permission from the ethics committee of faculty for the study (E. 116795). Results: In the patient group with septum deviation, pulmonary artery pressure was high. In addition, the size of the right heart chambers was also increased. TAPSE, pulmonary acceleration time, ejection fraction, and right ventricular outflow tractfractional shortening were found to be lower than the normal group. Conclusion: Patients with obstructive septum deviations should be evaluated early for cardiologic functions.
dc.identifier.doi10.1097/SCS.0000000000004742
dc.identifier.endpage2152
dc.identifier.issn1049-2275
dc.identifier.issn1536-3732
dc.identifier.issue8
dc.identifier.pmid30028402
dc.identifier.scopus2-s2.0-85056401284
dc.identifier.scopusqualityQ3
dc.identifier.startpage2148
dc.identifier.urihttps://doi.org/10.1097/SCS.0000000000004742
dc.identifier.urihttps://hdl.handle.net/20.500.12428/27522
dc.identifier.volume29
dc.identifier.wosWOS:000467707800064
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectCardiac problems
dc.subjectECHO
dc.subjectnasal septum
dc.subjectupper airway resistance
dc.titleEvaluation of Heart Functions With Detailed Echocardiogram in Patients With Septum Deviation
dc.typeArticle

Dosyalar