Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters

dc.authoridÖztürk, Habibe / 0000-0002-5985-9421
dc.authoridDeniz, Yeşim / 0000-0002-6967-5378
dc.contributor.authorUlusoy Öztürk, Habibe
dc.contributor.authorDeniz, Yeşim
dc.contributor.authorAktaş, Çağatay
dc.contributor.authorGül Aygün, Esma Başak
dc.date.accessioned2025-01-27T20:26:53Z
dc.date.available2025-01-27T20:26:53Z
dc.date.issued2023
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractObjective: This study aimed to assess the effects of denture materials on dose distribution on a head and neck radiotherapy-appropriate model and calculate the thickness of a stent by polyvinyl siloxane dental impression material for shielding scattered radiation from dental restorations. Methods: In the first step of the study, 5mm diameter and 5mm height of cylindrical dental material of titanium, zirconia lithium disilicate were irradiated with 6-Megavoltage photons from a clinical linear accelerator. In the second step, dental materials at the center of polyvinyl siloxane thicknesses of 5, 10, and 20mm were irradiated with 2 Gray and 10 Gray fractional doses. Measurements were made using three thermoluminescent dosimeters positioned laterally. The percentage backscattered dose and percentage dose decrease values were calculated to interpret the results. Results: According to the result, dosages scattered from dental materials increased for samples irradiated with 2Gy; a decreased dose was reported for samples irradiated with a 10Gy. 5mm PVS samples provided higher dose attenuation than others. Regardless of dental material, it is seen that the attenuation intensities calculated from TLD-100 dosimeters ranged from 22.7 to 38,62 for 2Gy, and 10.01 to 38,87 for 10Gy. Conclusion: Dental material alters the scattered radiation. In irradiated head and neck cancer patients, a 5mm thick guard is sufficient to prevent radiation diffused from dental materials in clinical usage.
dc.description.sponsorshipScientific Research Commission of Canakkale Onsekiz Mart University [THD-2019-3029]
dc.description.sponsorshipThis work was supported by The Scientific Research Commission of Canakkale Onsekiz Mart University [Project No: THD-2019-3029] .
dc.identifier.doi10.33808/clinexphealthsci.1194836
dc.identifier.endpage702
dc.identifier.issn2459-1459
dc.identifier.issue4
dc.identifier.startpage696
dc.identifier.trdizinid1218062
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.1194836
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1218062
dc.identifier.urihttps://hdl.handle.net/20.500.12428/22483
dc.identifier.volume13
dc.identifier.wosWOS:001136734600011
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherMarmara University
dc.relation.ispartofClinical and Experimental Health Sciences
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20250125
dc.subjectRadiotherapy
dc.subjectpolyvinylsiloxane
dc.subjectTLD
dc.subjectdose distribution
dc.titleInvestigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Habibe Ozturk Ulusoy_Makale.pdf
Boyut:
808.46 KB
Biçim:
Adobe Portable Document Format