Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters

dc.authoridozturk, habibe/0000-0002-5985-9421
dc.authoriddeniz, yesim/0000-0002-6967-5378
dc.contributor.authorUlusoy, Habibe Ozturk
dc.contributor.authorDeniz, Yesim
dc.contributor.authorAktas, Cagatay
dc.contributor.authorAygun, Esma Basak Gull
dc.date.accessioned2025-01-27T20:26:53Z
dc.date.available2025-01-27T20:26:53Z
dc.date.issued2023
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractObjective: This study aimed to assess the effects of denture materials on dose distribution on a head and neck radiotherapy-appropriate model and calculate the thickness of a stent by polyvinyl siloxane dental impression material for shielding scattered radiation from dental restorations. Methods: In the first step of the study, 5mm diameter and 5mm height of cylindrical dental material of titanium, zirconia lithium disilicate were irradiated with 6-Megavoltage photons from a clinical linear accelerator. In the second step, dental materials at the center of polyvinyl siloxane thicknesses of 5, 10, and 20mm were irradiated with 2 Gray and 10 Gray fractional doses. Measurements were made using three thermoluminescent dosimeters positioned laterally. The percentage backscattered dose and percentage dose decrease values were calculated Results: According to the result, dosages scattered from dental materials increased for samples irradiated with 2Gy; a decreased dose was reported for samples irradiated with a 10Gy. 5mm PVS samples provided higher dose attenuation than others. Regardless of dental material, it is seen that the attenuation intensities calculated from TLD-100 dosimeters ranged from 22.7 to 38,62 for 2Gy, and 10.01 to 38,87 for 10Gy. Conclusion: Dental material alters the scattered radiation. In irradiated head and neck cancer patients, a 5mm thick guard is sufficient to prevent radiation diffused from dental materials in clinical usage.
dc.description.sponsorshipScientific Research Commission of Canakkale Onsekiz Mart University [THD-2019-3029]
dc.description.sponsorshipThis work was supported by The Scientific Research Commission of Canakkale Onsekiz Mart University [Project No: THD-2019-3029] .
dc.identifier.doi10.33808/clinexphealthsci.1194836
dc.identifier.endpage702
dc.identifier.issn2459-1459
dc.identifier.issue4
dc.identifier.startpage696
dc.identifier.trdizinid1218062
dc.identifier.urihttps://doi.org/10.33808/clinexphealthsci.1194836
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1218062
dc.identifier.urihttps://hdl.handle.net/20.500.12428/22483
dc.identifier.volume13
dc.identifier.wosWOS:001136734600011
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherMarmara Univ, Inst Health Sciences
dc.relation.ispartofClinical and Experimental Health Sciences
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20250125
dc.subjectRadiotherapy
dc.subjectpolyvinylsiloxane
dc.subjectTLD
dc.subjectdose distribution.
dc.titleInvestigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters