Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters
dc.authorid | ozturk, habibe/0000-0002-5985-9421 | |
dc.authorid | deniz, yesim/0000-0002-6967-5378 | |
dc.contributor.author | Ulusoy, Habibe Ozturk | |
dc.contributor.author | Deniz, Yesim | |
dc.contributor.author | Aktas, Cagatay | |
dc.contributor.author | Aygun, Esma Basak Gull | |
dc.date.accessioned | 2025-01-27T20:26:53Z | |
dc.date.available | 2025-01-27T20:26:53Z | |
dc.date.issued | 2023 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | Objective: This study aimed to assess the effects of denture materials on dose distribution on a head and neck radiotherapy-appropriate model and calculate the thickness of a stent by polyvinyl siloxane dental impression material for shielding scattered radiation from dental restorations. Methods: In the first step of the study, 5mm diameter and 5mm height of cylindrical dental material of titanium, zirconia lithium disilicate were irradiated with 6-Megavoltage photons from a clinical linear accelerator. In the second step, dental materials at the center of polyvinyl siloxane thicknesses of 5, 10, and 20mm were irradiated with 2 Gray and 10 Gray fractional doses. Measurements were made using three thermoluminescent dosimeters positioned laterally. The percentage backscattered dose and percentage dose decrease values were calculated Results: According to the result, dosages scattered from dental materials increased for samples irradiated with 2Gy; a decreased dose was reported for samples irradiated with a 10Gy. 5mm PVS samples provided higher dose attenuation than others. Regardless of dental material, it is seen that the attenuation intensities calculated from TLD-100 dosimeters ranged from 22.7 to 38,62 for 2Gy, and 10.01 to 38,87 for 10Gy. Conclusion: Dental material alters the scattered radiation. In irradiated head and neck cancer patients, a 5mm thick guard is sufficient to prevent radiation diffused from dental materials in clinical usage. | |
dc.description.sponsorship | Scientific Research Commission of Canakkale Onsekiz Mart University [THD-2019-3029] | |
dc.description.sponsorship | This work was supported by The Scientific Research Commission of Canakkale Onsekiz Mart University [Project No: THD-2019-3029] . | |
dc.identifier.doi | 10.33808/clinexphealthsci.1194836 | |
dc.identifier.endpage | 702 | |
dc.identifier.issn | 2459-1459 | |
dc.identifier.issue | 4 | |
dc.identifier.startpage | 696 | |
dc.identifier.trdizinid | 1218062 | |
dc.identifier.uri | https://doi.org/10.33808/clinexphealthsci.1194836 | |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1218062 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/22483 | |
dc.identifier.volume | 13 | |
dc.identifier.wos | WOS:001136734600011 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | TR-Dizin | |
dc.language.iso | en | |
dc.publisher | Marmara Univ, Inst Health Sciences | |
dc.relation.ispartof | Clinical and Experimental Health Sciences | |
dc.relation.publicationcategory | info:eu-repo/semantics/openAccess | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_WoS_20250125 | |
dc.subject | Radiotherapy | |
dc.subject | polyvinylsiloxane | |
dc.subject | TLD | |
dc.subject | dose distribution. | |
dc.title | Investigation of Dosage Distributions of Polyvinyl Siloxane Dental Impression Shields for Head and Neck Radiotherapy with Thermoluminances Dosimeters | |
dc.type | Article |