Flow injection amperometric determination of NADH at a calmagite-modified pencil graphite electrode

dc.authoridDilgin, Yusuf/0000-0002-2980-6871
dc.contributor.authorGunes, Mehmet
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2025-01-27T20:32:04Z
dc.date.available2025-01-27T20:32:04Z
dc.date.issued2019
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractIn this study, an aromatic sulfonic dye, Calmagite (Calm) was electropolymerized on a pencil graphite electrode (Poly-Calm/PGE) to investigate the electrocatalytic oxidation and flow injection (FI) amperometric detection of NADH. Cyclic voltammetric studies show that Poly-Calm/PGE exhibits a high electrocatalytic activity towards the oxidation of NADH. Then, determination of NADH was performed at Poly-Calm/PGE using FI-amperometric technique with a homemade flow cell which was fabricated for PGEs. FI-amperometric measurements showed that linear response of NADH was found between 0.10 and 100.0 mu M. Detection limit was found as 0.03 mu M (based on 3 S-b/m) at Poly-Calm/PGE. This study is the first one for FI-amperometric analysis of NADH using Poly-Calm/PGE which provides a simple, low cost, and sensitive determination of NADH. The proposed sensor can be a good alternative method for determination of NADH and construction of a biosensor based on dehydrogenase enzyme in future. [GRAPHICS] .
dc.description.sponsorshipTUBITAK (Scientific and Technological Research Council of Turkey) [115Z235]
dc.description.sponsorshipThe authors would like to thank the TUBITAK (Scientific and Technological Research Council of Turkey) for the financial support (Grant number: 115Z235). This work includes a part of TUBITAK project and Ph.D. thesis of Mehmet Gunes.
dc.identifier.doi10.1007/s00706-019-02446-y
dc.identifier.endpage1432
dc.identifier.issn0026-9247
dc.identifier.issn1434-4475
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85068109287
dc.identifier.scopusqualityQ2
dc.identifier.startpage1425
dc.identifier.urihttps://doi.org/10.1007/s00706-019-02446-y
dc.identifier.urihttps://hdl.handle.net/20.500.12428/23342
dc.identifier.volume150
dc.identifier.wosWOS:000477624300004
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSpringer Wien
dc.relation.ispartofMonatshefte Fur Chemie
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectPencil graphite electrode
dc.subjectNADH
dc.subjectFlow injection analysis
dc.subjectCyclic voltammetry
dc.subjectSensors
dc.subjectElectrochemistry
dc.titleFlow injection amperometric determination of NADH at a calmagite-modified pencil graphite electrode
dc.typeArticle

Dosyalar