The Effects of Heart-to-Mobile Phone Distance on the Circulatory System

dc.authorid0000-0002-4478-4324en_US
dc.authorscopusid56819132600en_US
dc.authorwosid-en_US
dc.contributor.authorAydın, Fatih
dc.contributor.authorAkşit, Ercan
dc.contributor.authorAydın, Ayşe Hüseyinoğlu
dc.contributor.authorYıldırım, Özge Turgay
dc.date.accessioned2023-04-03T07:18:57Z
dc.date.available2023-04-03T07:18:57Z
dc.date.issued2021en_US
dc.departmentFakülteler, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü
dc.description.abstractAmaç: Cep telefonu ile kalp arasındaki mesafenin kalp hızı değişkenliğine (KHD) etkisi incelenerek cep telefonunun kalbe olan uzaklığının dolaşım sistemine etkisi araştırıldı. Gereç ve Yöntem: Cep telefonu kullanan sağlıklı gönüllüler çalışmaya dahil edildi. Kalbin sağ kulağa uzaklığı, sol kulağa olan uzaklığından yaklaşık dört santimetre daha fazladır. Bu mesafe farkından yararlanılarak gönüllüler sağ el baskın ve sol el baskın bireyler olarak iki gruba ayrıldı. Toplam 31 sağ el baskın (Grup 1) ve 32 sol el baskın (Grup 2) gönüllü kaydedildi. KHD, piyasada bulunan FDA onaylı üç kanallı Holter izleme cihazı (Holter ECG Kaydedici DMS300-4A) tarafından otomatik olarak hesaplandı. Bulgular: Birinci grubun ortalama tragustan apekse mesafesi 37,5 cm ve ikinci grubun ortalaması 33,6 cm idi. N – Ns (SDNN) standart sapması, N – Ns (SDANN) 5 dakikalık ortalama değerlerinin standart sapması, N – Ns (RMSSD) karekök ortalama ardışık farkı (RMSSD), düşük frekans (LF) ve yüksek frekans (HF) değerleri ve iki grup arasındaki LF / HF oranı arasında istatistiksel olarak anlamlı bir fark yoktu. Her 5 dakikalık aralık için 50 ms'den büyük olan ardışık N-N farklarının yüzdesi (pNN% 50) Grup 2'de Grup 1'e göre anlamlı olarak daha düşüktü (p = 0,014). Sonuç: Bulgularımız, cep telefonu kalp mesafesindeki küçük bir artışın bile kardiyovasküler sistem üzerindeki olumsuz etkilerini azaltabileceğini göstermektedir.en_US
dc.description.abstractObjective: The effect of the change in the distance between the mobile phone(MP) and the heart on heart rate variability (HRV) was examined, and the influence of the MP's distance to heart on the circulatory system was investigated. Methods: Healthy volunteers using MPs were included in this study. The distance from the heart to the right ear is about four centimeters greater than its distance to the left ear. Taking advantage of this distance difference, the volunteers were divided into two groups: right-hand dominant and left-hand dominant individuals. A total of 31 righthand dominant (Group 1) and 32 left-hand dominant (Group 2) volunteers were enrolled. HRV was automatically calculated by a commercially available FDA-approved three-channel Holter monitoring device (Holter ECG Recorder DMS300-4A. Results: The mean tragus to apex distance of the first group was 37.5 cm and the mean of the second group was 33.6 cm. There was no statistically significant difference between standard deviation of N–Ns (SDNN), the standard deviation of the 5-min mean values of N–Ns (SDANN), root mean square successive difference of N–Ns (RMSSD), low-frequency (LF), and high frequency (HF) values and LF/HF ratio between the two groups. The percentage of successive N–N differences that were greater than 50 ms for each 5-min interval (pNN50%) was significantly lower in Group 2 compared to Group 1 (p = 0.014). Conclusions: Our findings show that even a small increase in MPs to heart distance can reduce its negative effects on the cardiovascular system.en_US
dc.identifier.citationAydın, F. , Akşit, E. , Hüseyinoğlu Aydın, A. & Turgay Yıldırım, Ö. (2021). The Effects of Heart-to-Mobile Phone Distance on the Circulatory System. Konuralp Medical Journal, 13(1), 130-134 . DOI: 10.18521/ktd.835364en_US
dc.identifier.doi10.18521/ktd.835364
dc.identifier.endpage134en_US
dc.identifier.issn1309–3878
dc.identifier.issue1en_US
dc.identifier.startpage130en_US
dc.identifier.trdizinid427863
dc.identifier.urihttps://doi.org/10.18521/ktd.835364
dc.identifier.urihttps://hdl.handle.net/20.500.12428/3905
dc.identifier.volume13en_US
dc.identifier.wosWOS:000628768700020
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorAkşit, Ercan
dc.language.isoen
dc.publisherDüzce Üniversitesi Tıp Fakültesien_US
dc.relation.ispartofKonuralp Medical Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCardiac Autonomic Modulationen_US
dc.subjectElectromagnetic Fielden_US
dc.subjectHeart Rate Variabilityen_US
dc.subjectMobile Phoneen_US
dc.subjectKardiyak Otonomik Modülasyonen_US
dc.subjectElektromanyetik Alanen_US
dc.subjectKalp Hızı Değişkenliğien_US
dc.subjectCep Telefonuen_US
dc.titleThe Effects of Heart-to-Mobile Phone Distance on the Circulatory System
dc.title.alternativeKalp-Cep Telefonu Mesafesinin Dolaşım Sistemine Etkileri
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Ercan_Aksit_Makale.pdf
Boyut:
529.12 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Araştırma Makalesi
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: