A new transodontoid fixation technique for delayed type II odontoid fracture: technical note
dc.contributor.author | Ozer, A. Fahir | |
dc.contributor.author | Cosar, Murat | |
dc.contributor.author | Oktenoglu, Tunc B. | |
dc.contributor.author | Sasani, Mehdi | |
dc.contributor.author | Iplikcioglu, A. Celal | |
dc.contributor.author | Bozkus, Hakan | |
dc.contributor.author | Bavbek, Cengiz | |
dc.date.accessioned | 2025-01-27T20:14:50Z | |
dc.date.available | 2025-01-27T20:14:50Z | |
dc.date.issued | 2009 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | Background: A different transodontoid screw fixation technique Was studied in delayed type II odontoid fractures. This study presents observations oil a different transodontoid fixation technique to remove and decrease the amount of sclerotic layers to accelerate the Fusion process after the operation. Methods: Ten cases of chromic type II odontoid fractures, were operated oil via transodontoid screw fixation between 2000 and 2007 which were admitted 6 weeks or later after the trauma. Four of these 10 delayed patients were operated oil using a new anterior transodontoid screw fixation technique, whereas the other 6 delayed patients were operated On using, classical anterior transodontoid screw fixation. Results: Four delayed cases with type It odontoid fracture operated oil via this new technique had good results throughout the minimum 38 months' follow-up period. We did not observe nonunion, infection, and/or other complications such as vascular or brain-stern injury. Conclusion: Transodontoid screw fixation should be considered as a preferable treatment modality. This surgical intervention may be all alternative to conservative treatment even for cases with delayed type II odontoid fractures. (C) 2009 Elsevier Inc. All rights reserved. | |
dc.identifier.doi | 10.1016/j.surneu.2007.09.027 | |
dc.identifier.endpage | 125 | |
dc.identifier.issn | 0090-3019 | |
dc.identifier.issue | 1 | |
dc.identifier.pmid | 18295847 | |
dc.identifier.scopus | 2-s2.0-57349175562 | |
dc.identifier.scopusquality | N/A | |
dc.identifier.startpage | 121 | |
dc.identifier.uri | https://doi.org/10.1016/j.surneu.2007.09.027 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/21212 | |
dc.identifier.volume | 71 | |
dc.identifier.wos | WOS:000262098400023 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | |
dc.publisher | Elsevier Science Inc | |
dc.relation.ispartof | Surgical Neurology | |
dc.relation.publicationcategory | info:eu-repo/semantics/openAccess | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_WoS_20250125 | |
dc.subject | Cervical trauma | |
dc.subject | Odontoid screw fixation | |
dc.subject | Type II odontoid fracture | |
dc.title | A new transodontoid fixation technique for delayed type II odontoid fracture: technical note | |