Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor

dc.authoriduzun, metehan/0000-0003-1406-5473
dc.contributor.authorErsan, Ismail
dc.contributor.authorArikan, Sedat
dc.contributor.authorToman, Huseyin
dc.contributor.authorKara, Selcuk
dc.contributor.authorGencer, Baran
dc.contributor.authorErbas, Mesut
dc.contributor.authorTufan, Hasan Ali
dc.date.accessioned2025-01-27T20:14:11Z
dc.date.available2025-01-27T20:14:11Z
dc.date.issued2015
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractPurpose: To measure the partial pressure of oxygen (PO2) and carbon dioxide (PCO2) and the pH of aqueous humor (AH) and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 +/- 15.0 mmHg. The mean blood and AH PO2 were 95.18 +/- 11.76 mmHg and 88.83 +/- 9.92 mmHg, the mean blood and AH PCO2 were 25.86 +/- 5.46 mmHg and 29.50 +/- 5.36 mmHg, and the mean blood and AH pH were 7.38 +/- 0.06 and 7.33 +/- 0.09, respectively. Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies.
dc.identifier.doi10.5935/0004-2749.20150022
dc.identifier.endpage84
dc.identifier.issn0004-2749
dc.identifier.issn1678-2925
dc.identifier.issue2
dc.identifier.pmid25945527
dc.identifier.scopus2-s2.0-84942627219
dc.identifier.scopusqualityQ3
dc.identifier.startpage82
dc.identifier.urihttps://doi.org/10.5935/0004-2749.20150022
dc.identifier.urihttps://hdl.handle.net/20.500.12428/20978
dc.identifier.volume78
dc.identifier.wosWOS:000354050800005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherConsel Brasil Oftalmologia
dc.relation.ispartofArquivos Brasileiros De Oftalmologia
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WoS_20250125
dc.subjectAqueous humor
dc.subjectBlood gas analysis
dc.subjectOxygen/physiology
dc.subjectCarbon dioxide/physiology
dc.subjectRabbits
dc.titleBlood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor
dc.typeArticle

Dosyalar