Evaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump

dc.authoridMotorcu, Ali Rıza/0000-0002-9129-8935
dc.contributor.authorCoskun, Salih
dc.contributor.authorMotorcu, Ali Rıza
dc.contributor.authorYamankaradeniz, Nurettin
dc.contributor.authorPulat, Erhan
dc.date.accessioned2025-01-27T20:49:30Z
dc.date.available2025-01-27T20:49:30Z
dc.date.issued2012
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractThis paper deals with an investigation of the effect and optimization of control parameters on the system performance in waste heat recovery application using mechanical heat pump (MHP). The experimental studies have been conducted under varying compressor speed, wastewater temperature and flow rate. The experiments have been planned based on Taguchi's L27 orthogonal array with each trial performed under different conditions of compressor's speed, wastewater temperature and flow rate. The optimum parameter combination has been obtained by using the analysis of signal-to-noise (S/N) ratio. The level of importance of the control parameters on the system performance has been determined by using analysis of variance (ANOVA). Main effects plots and interaction effects plots have been utilized to optimize and analyze the relation between the control parameters and the system performance. The results obtained from Taguchi method were also compared with ANN results. The experimental study indicated that it is possible to increase system performance significantly in the waste heat recovery application using MHP. (C) 2011 Elsevier Ltd and IIR. All rights reserved.
dc.description.sponsorshipCommission of Scientific Research Projects of Uludag University [M-2008/63]
dc.description.sponsorshipThis work was supported by The Commission of Scientific Research Projects of Uludag University, project number: M-2008/63.
dc.identifier.doi10.1016/j.ijrefrig.2011.12.008
dc.identifier.endpage809
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.issue4
dc.identifier.scopus2-s2.0-84861226963
dc.identifier.scopusqualityQ1
dc.identifier.startpage795
dc.identifier.urihttps://doi.org/10.1016/j.ijrefrig.2011.12.008
dc.identifier.urihttps://hdl.handle.net/20.500.12428/25189
dc.identifier.volume35
dc.identifier.wosWOS:000305655300007
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Sci Ltd
dc.relation.ispartofInternational Journal of Refrigeration-Revue Internationale Du Froid
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectHeat pump
dc.subjectHeat recovery
dc.subjectMechanical vapor compression
dc.subjectWastewater
dc.subjectWaste heat
dc.subjectTaguchi
dc.titleEvaluation of control parameters' effects on system performance with Taguchi method in waste heat recovery application using mechanical heat pump