Non-destructive damage analysis in Kariye (Chora) Museum as a cultural heritage building

dc.authoridYALCINER, CAHIT CAGLAR/0000-0003-0470-303X
dc.contributor.authorYalciner, C. Caglar
dc.contributor.authorBuyuksarac, Aydin
dc.contributor.authorKurban, Yunus Can
dc.date.accessioned2025-01-27T20:34:41Z
dc.date.available2025-01-27T20:34:41Z
dc.date.issued2019
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractNon-destructive testing methods are being increasingly used in the evaluation of cultural heritage buildings. Combined geophysical methods especially can be applied to structural evaluations of these kinds of buildings. Ultrasonic Pulse Velocity (UPV) Test and Ground Penetrating Radar (GPR) were used in a complementary way as non-destructive testing techniques in this study. The main aim of the study is to analyze the internal structural configuration as well as the quality of the stone, internal geometry and physical properties of some structural elements. It was determined that the main cracks in all walls within the building are on an axis. The cracks on this crack axis were determined to have been filled during previous repairs on the GPR profiles. However, the filling material is different from the building materials that constitute the building walls and at the same time the presence of void spaces was determined. (C) 2019 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.jappgeo.2019.103874
dc.identifier.issn0926-9851
dc.identifier.issn1879-1859
dc.identifier.scopus2-s2.0-85074439383
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1016/j.jappgeo.2019.103874
dc.identifier.urihttps://hdl.handle.net/20.500.12428/23423
dc.identifier.volume171
dc.identifier.wosWOS:000500374300013
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Applied Geophysics
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectKariye (Chora) Museum
dc.subjectGPR
dc.subjectUltrasonic Pulse Velocity (UPV)
dc.subjectGeophysics
dc.subjectNon-destructive testing
dc.titleNon-destructive damage analysis in Kariye (Chora) Museum as a cultural heritage building