Comparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia
dc.authorid | uzun, metehan/0000-0003-1406-5473 | |
dc.contributor.author | Toman, Huseyin | |
dc.contributor.author | Erbas, Mesut | |
dc.contributor.author | Sahin, Hasan | |
dc.contributor.author | Kiraz, Hasan Ali | |
dc.contributor.author | Uzun, Metehan | |
dc.contributor.author | Ovali, Mehmet Akif | |
dc.date.accessioned | 2025-01-27T20:41:24Z | |
dc.date.available | 2025-01-27T20:41:24Z | |
dc.date.issued | 2015 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | In this study, we aimed to compare the effects of various airway devices on QTc interval in rabbits under general anesthesia. The subjects were randomly separated into four groups: Group ETT, Group LMA, Group PLA, Group V-gel. Baseline values and hearth rate, mean arterial pressure and ECG was obtained at the 1st, 5th and 30th minutes after administration of anesthesia and placement of airway device and, QTc interval was evaluated. Difference was observed between ET group and V-gel group in the 5th minute mean arterial pressure values (p < 0.05). It was observed that QTc intervals at the 1st and 5th minute in the ET group significantly increased when compared with the other groups (p < 0.05). Again, it was observed that QTc interval of ET group at the 15th and 30th minute was longer when compared with PLA and V-gel groups (p < 0.05). It was also observed that QTc interval of LMA Group at the 5th minute after intubation significantly increased when compared with V-gel group (p < 0.05). It was observed that HR values of ETT group at the 1st, 5th and 15th minutes after intubation increased with regards to PLA and V-gel groups (p < 0.05). It was determined that the 30th minute hearth rate of ETT group was higher when compared to V-gel group (p < 0.05). Conclusion: In our study we observed that V-gel Rabbit affected both hemodynamic response and QT interval less than other airway devices. | |
dc.description.sponsorship | Canakkale Onsekiz Mart University Scientific Research Project Found [TSA-2013-80] | |
dc.description.sponsorship | This study was supported by Canakkale Onsekiz Mart University Scientific Research Project Found with TSA-2013-80 project number. The authors has no financial relationship with the companies that manufactured the materials used in this study. | |
dc.identifier.doi | 10.1007/s10877-015-9659-x | |
dc.identifier.endpage | 732 | |
dc.identifier.issn | 1387-1307 | |
dc.identifier.issn | 1573-2614 | |
dc.identifier.issue | 6 | |
dc.identifier.pmid | 25637244 | |
dc.identifier.scopus | 2-s2.0-84945456498 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 727 | |
dc.identifier.uri | https://doi.org/10.1007/s10877-015-9659-x | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/24130 | |
dc.identifier.volume | 29 | |
dc.identifier.wos | WOS:000363554100009 | |
dc.identifier.wosquality | Q3 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | |
dc.publisher | Springer Heidelberg | |
dc.relation.ispartof | Journal of Clinical Monitoring and Computing | |
dc.relation.publicationcategory | info:eu-repo/semantics/openAccess | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_WoS_20250125 | |
dc.subject | Endotracheal intubation | |
dc.subject | Laryngeal mask airway | |
dc.subject | Cobra PLA | |
dc.subject | V-gel Rabbit | |
dc.subject | Supraglottic airway | |
dc.subject | QTc | |
dc.subject | Hemodynamic response | |
dc.title | Comparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia | |
dc.type | Article |