Determination of total Cr in wastewaters of Cr electroplating factories in the I.organize industry region (Kayseri, Turkey) by ICP-AES

dc.authoridYilmaz, Selehattin/0000-0003-4607-3523
dc.authoridDuran, Ali/0000-0002-6260-2424
dc.contributor.authorYilmaz, Selehattin
dc.contributor.authorTure, Melike
dc.contributor.authorSadikoglu, Murat
dc.contributor.authorDuran, Ali
dc.date.accessioned2025-01-27T21:00:17Z
dc.date.available2025-01-27T21:00:17Z
dc.date.issued2010
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractThe wastewater pollution in industrial areas is one of the most important environmental problems. Heavy metal pollution, especially chromium pollution in the wastewater sources from electroplating, dyeing, and tannery, has affected the life on earth. This pollution can affect on all ecosystems and human health directly or by food chain. Therefore, the determination of total chromium in this study is of great importance. In this study, accurate, rapid, sensitive, selective, simple, and low-cost technique for the direct determination of total Cr in wastewater samples collected from the some Cr electroplating factories in March 2008 by inductively coupled plasma-atomic emission spectrometry has been developed. The analysis of a given sample is completed in about 15 min by this technique applied. As the result of the chromium analysis, the limit of quantification for the total Cr were founded to be over the limit value (0.05 mg L (-aEuro parts per thousand 1); WHO, EPA, TSE 266, and inland water quality classification) as 1,898.78 +/- 0.34 mg/L at station 1 and 3,189.02 +/- 0.56 mg/L at station 2. The found concentration of total Cr has been determined to be IV class quality water according to the inland water classification. In order to validate the applied method, recovery studies were performed.
dc.identifier.doi10.1007/s10661-009-1045-z
dc.identifier.endpage242
dc.identifier.issn0167-6369
dc.identifier.issn1573-2959
dc.identifier.issue1-4
dc.identifier.pmid19565347
dc.identifier.scopus2-s2.0-77956191771
dc.identifier.scopusqualityQ2
dc.identifier.startpage235
dc.identifier.urihttps://doi.org/10.1007/s10661-009-1045-z
dc.identifier.urihttps://hdl.handle.net/20.500.12428/26985
dc.identifier.volume167
dc.identifier.wosWOS:000279683100019
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofEnvironmental Monitoring and Assessment
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectChromium
dc.subjectChromium-electroplating
dc.subjectWater pollution
dc.subjectWastewater analysis
dc.subjectDetermination
dc.subjectICP-AES
dc.titleDetermination of total Cr in wastewaters of Cr electroplating factories in the I.organize industry region (Kayseri, Turkey) by ICP-AES
dc.typeArticle

Dosyalar