Comparison of pediatric doses of cone beam computed tomography and panoramic radiography in three age groups

dc.authoridDeniz, Yeşim / 0000-0002-6967-5378
dc.authoridEren, Hakan / 0000-0001-9006-6836
dc.authoridSessiz, Rüya / 0000-0001-5487-6751
dc.contributor.authorEren, Hakan
dc.contributor.authorDeniz, Yeşim
dc.contributor.authorAta, G.C.
dc.contributor.authorSessiz, Rüya
dc.date.accessioned2025-05-29T02:54:18Z
dc.date.available2025-05-29T02:54:18Z
dc.date.issued2025
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractBackground: A wide variety of radiation dose values can occur in Cone Beam Computed Tomography (CBCT) devices with different field of view (FOV) sizes. Radiation dose of current CBCT devices have been considerably reduced. This study compared effective radiation doses and organ absorption doses obtained from panoramic and CBCT imaging at various FOV sizes in children aged five, ten, and fifteen years. Materials and Methods: To calculate the organ doses and effective doses, a dose calculation software PC-based Monte Carlo (PCXMC) 2.0 based on Monte-Carlo simulation was used for CBCT and panoramic exposures. Both absorbed and effective doses were calculated for the simulated phantoms of 5, 10 and 15 years old separately. Results: The organ doses of thyroid and salivary glands measured with 6*6 ECO Scan CBCT were found to be lower when compared with panoramic radiography organ doses. Panoramic radiography effective doses were lower than all other CBCT modes in all age groups. Conclusion: Although it is stated that this study does not have diagnostic data, it is thought that 6×6 ECO Scan Mode of Newtom CBCT can be chosen instead of panoramic radiography in children aged 5 years due to the dose differences. © 2025 Novin Medical Radiation Institute. All rights reserved.
dc.identifier.doi10.61186/ijrr.23.1.193
dc.identifier.endpage199
dc.identifier.issn2322-3243
dc.identifier.issue1
dc.identifier.scopus2-s2.0-105004308068
dc.identifier.scopusqualityQ4
dc.identifier.startpage193
dc.identifier.urihttps://doi.org/10.61186/ijrr.23.1.193
dc.identifier.urihttps://hdl.handle.net/20.500.12428/29990
dc.identifier.volume23
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherNovin Medical Radiation Institute
dc.relation.ispartofInternational Journal of Radiation Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_Scopus_20250529
dc.subjectCBCT
dc.subjectdiagnostic imaging
dc.subjectRadiation dosage
dc.subjectradiation effect
dc.titleComparison of pediatric doses of cone beam computed tomography and panoramic radiography in three age groups
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Yesim Deniz_Makale.pdf
Boyut:
593.29 KB
Biçim:
Adobe Portable Document Format