Assessment of Soil-Structure Interaction in Reinforced Concrete Buildings Based on Structure to Soil Stiffness Ratio
dc.contributor.author | Ozgur, Mehmet | |
dc.contributor.author | Bozdogan, Kanat Burak | |
dc.date.accessioned | 2025-01-27T19:00:44Z | |
dc.date.available | 2025-01-27T19:00:44Z | |
dc.date.issued | 2023 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | Soil-structure interaction (SSI) results in higher structural damping ratio and elongated fundamental natural period of the building. Generally, these modifications on dynamic properties of the building are regarded to be favorable for dynamic response and SSI is neglected in most of the design codes. However, extensive research points out that neglecting the role of SSI can be a misconception that lead an unsafe design by underestimating the rotational ductility demand and top displacement of the building. Therefore, it is essential to determine if SSI is expected to be significant for safe design of the buildings. In this study, the significance of SSI in design is assessed with the help of the structure to soil stiffness ratio that is considered as the most important parameter controlling the period elongation. Stiffness ratio is determined for buildings with moment-resisting frames and varying number of storeys resting on different soil conditions and a threshold of 0.1 is assumed as the critical value that yields a period elongation of 5%. It is shown that, SSI should be taken into account for buildings founded on site classes ZE, ZD and ZC and can be neglected for site classes ZB and ZA. © 2023 The Author(s). | |
dc.identifier.doi | 10.46464/tdad.1184558 | |
dc.identifier.endpage | 84 | |
dc.identifier.issn | 2687-301X | |
dc.identifier.issue | 1 | |
dc.identifier.scopus | 2-s2.0-85168807898 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 69 | |
dc.identifier.trdizinid | 1183718 | |
dc.identifier.uri | https://doi.org/10.46464/tdad.1184558 | |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1183718 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/13445 | |
dc.identifier.volume | 5 | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | TR-Dizin | |
dc.language.iso | tr | |
dc.publisher | Afet ve Acil Durum Yonetimi Baskanligi (AFAD) | |
dc.relation.ispartof | Turk Deprem Arastirma Dergisi | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_Scopus_20250125 | |
dc.subject | Period elongation; Soil-structure interaction; Stiffness ratio | |
dc.title | Assessment of Soil-Structure Interaction in Reinforced Concrete Buildings Based on Structure to Soil Stiffness Ratio | |
dc.title.alternative | Betonarme Binalarda Zemin-Yapı Etkileşiminin Yapının Zemine Rijitlik Oranı Yardımıyla Değerlendirilmesi | |
dc.type | Article |