A novel ultrasensitive immunosensor based on disposable graphite paper electrodes for troponin T detection in cardiovascular disease
dc.contributor.author | Demirbakan, Burcak | |
dc.contributor.author | Sezgintürk, Mustafa Kemal | |
dc.date.accessioned | 2025-01-27T20:27:23Z | |
dc.date.available | 2025-01-27T20:27:23Z | |
dc.date.issued | 2020 | |
dc.department | Çanakkale Onsekiz Mart Üniversitesi | |
dc.description.abstract | Troponin T, which is a biomarker of cardiovascular disease, is vital for acute myocardial infarction (AMI). AMI is the most well-known cause of death in the world. In the present work, we designed a novel immunosensor using disposable, cheap, and very conductive graphite paper electrodes (GP). The proposed immunosensor was modified with hydrochloric acid (HCl) for immobilization of anti-TnT antibody. After carboxyl group formation on the surface, the GP electrodes were incubated with EDC/NHS pair as a cross-linker. Electrochemical impedance spectroscopy (EIS), single frequency impedance (SFI), cyclic voltammetry (CV) and square wave voltammetry (SWV) techniques were used for electrochemical characterization of the label-free immunosensor. Furthermore, the fabrication process of the proposed immunosensor was examined by using scanning electron microscopy (SEM). The proposed electrochemical immunosensor had a wide detection range (0.5 fg - 1000 fg/mL), and low limit of detection (LOD) and low limit of quantification (LOQ) at 1.28 fg/mL and 4.29 fg/mL, respectively. The designed immunosensor exhibited very good sensitivity, reproducibility, repeatability, reusability and long storage life. Additionally, the immunosensor was successfully applied to detection of TnT in human serum. | |
dc.identifier.doi | 10.1016/j.talanta.2020.120779 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.issn | 1873-3573 | |
dc.identifier.pmid | 32200916 | |
dc.identifier.scopus | 2-s2.0-85079331980 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.uri | https://doi.org/10.1016/j.talanta.2020.120779 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/22673 | |
dc.identifier.volume | 213 | |
dc.identifier.wos | WOS:000525711800001 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | |
dc.publisher | Elsevier | |
dc.relation.ispartof | Talanta | |
dc.relation.publicationcategory | info:eu-repo/semantics/openAccess | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_WoS_20250125 | |
dc.subject | Graphite paper (GP) | |
dc.subject | Troponin T (TnT) | |
dc.subject | Biosensor | |
dc.subject | Single frequency impedance (SFI) technique | |
dc.title | A novel ultrasensitive immunosensor based on disposable graphite paper electrodes for troponin T detection in cardiovascular disease | |
dc.type | Article |