Flow injection amperometric determination of hydrazine at a cupric-neocuproine complex/anionic surfactant modified disposable electrode

dc.contributor.authorAyaz, Selen
dc.contributor.authorDilgin, Yusuf
dc.contributor.authorApak, Resat
dc.date.accessioned2025-01-27T20:32:06Z
dc.date.available2025-01-27T20:32:06Z
dc.date.issued2020
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractHydrazine (N2H4) is a hazardous chemical widely used as rocket propellant and industrial intermediate, therefore its sensitive and accurate analysis in environmental samples is very important. In this study, a new approach for flow injection amperometric detection of N2H4 is proposed based on its electrocatalytic oxidation at a bis(neocuproine)copper (II) chelate complex/sodium dodecyl sulfate-modified graphite pencil electrode (Cu (II)-Ncp/SDS/GPE). The proposed electrode was prepared by consecutive adsorption of anionic surfactant (SDS) and Cu(II)-Ncp onto pencil leads and the surface morphologies of electrodes prepared were elucidated by recording of their SEM images. Cyclic voltammograms (CVs) showed that Cu(II)-Ncp exhibited an excellent redox mediator property for the electrocatalytic oxidation of N2H4, because oxidation potential of N2H4 at bare GPE shifted to more negative direction with the use of Cu(II)-Ncp/SDS/GPE. Then, flow injection (FI) electroanalysis of N2H4 was performed by utilizing the electrocatalytic oxidation of N2H4 at Cu(II)-Ncp/SDS/GPE. A wide linear range (0.25-250 mu M) with a limit of detection (LOD) of 0.07 mu M and a sensitivity of 262 mu AmM(-1)cm(-2) were obtained for the FI amperometric detection of N2H4. Satisfactory recoveries were obtained for N2H4 detection in water samples, showing that this method can be accurately applied to real water samples.
dc.identifier.doi10.1016/j.microc.2020.105457
dc.identifier.issn0026-265X
dc.identifier.issn1095-9149
dc.identifier.scopus2-s2.0-85090238359
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.microc.2020.105457
dc.identifier.urihttps://hdl.handle.net/20.500.12428/23350
dc.identifier.volume159
dc.identifier.wosWOS:000598762700007
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofMicrochemical Journal
dc.relation.publicationcategoryinfo:eu-repo/semantics/openAccess
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WoS_20250125
dc.subjectHydrazine
dc.subjectBis(neocuproine)copper (II) chelate complex
dc.subjectModified electrode
dc.subjectElectrocatalytic oxidation
dc.subjectFlow Injection Analysis
dc.titleFlow injection amperometric determination of hydrazine at a cupric-neocuproine complex/anionic surfactant modified disposable electrode