Determination of Tannic Acid Using Silica Gel Modified Carbon Paste Electrode

[ X ]

Tarih

2013

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Esg

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this paper, silica gel modified carbon paste electrode (Si-gel/CPE) was used for the determination of tannic acid (TA) by anodic stripping differential pulse voltammetry (ASDPV). The influences of pH values, amount of silica gel, accumulation potential and time on the signal enhancement of TA were optimized, and a novel electrochemical method for the determination of TA was reported. The currents obtained from ASDPV measurements at optimum conditions were linearly correlated with the concentration of TA. Calibration curve was obtained for TA concentrations in the range of 1 - 1000x10(-9) mol l(-1). The limit of detection was found to be 0.3x10(-9) mol l(-1). The results from TA measurements by Si-gel/CPE were in good agreement with those obtained from the standard spectrophotometric method.

Açıklama

Anahtar Kelimeler

tannic acid, silica gel, carbon paste electrode, anodic stripping differential pulse voltammetry

Kaynak

International Journal of Electrochemical Science

WoS Q Değeri

Q3

Scopus Q Değeri

Q3

Cilt

8

Sayı

7

Künye