Impacts of Valve Angle and Fluid Velocity on Pressure Drop in Pipe Flow

dc.contributor.authorEvran, Savaş
dc.date.accessioned2025-05-29T05:40:49Z
dc.date.available2025-05-29T05:40:49Z
dc.date.issued2022
dc.departmentÇanakkale Onsekiz Mart Üniversitesi
dc.description.abstractThe aim of this study is to evaluate the effects of valve angle and fluid velocity on pressure drop in pipe flow using ANSYS Fluent software. Flow analyses were conducted using Taguchi L8 orthogonal array with two control factors. The valve angle in the pipe was chosen as the first control factor, while the fluid velocity was selected as the second control factor. The optimum levels of each control factor and its effect on the results were determined using Signal-to-Noise ratio analysis. The significance level and contribution rates of each control factor on the responses were determined using analysis of variance. As a result of this study, the increase of fluid velocity and valve angle causes an increase in pressure drop. Maximum pressure and velocity changes were observed on the valve. It was determined that the effect of the fluid velocity in the pipe on the pressure drop was lower than the effect of the valve angle.
dc.identifier.endpage77
dc.identifier.issn2548-1185
dc.identifier.issn2587-2176
dc.identifier.issue3
dc.identifier.startpage73
dc.identifier.urihttps://hdl.handle.net/20.500.12428/32503
dc.identifier.volume6
dc.institutionauthorEvran, Savaş
dc.language.isoen
dc.publisherNişantaşı Üniversitesi
dc.relation.ispartofInternational Journal of Engineering Science and Application
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_DergiPark_20250529
dc.subjectANSYS Fluent
dc.subjectpipe
dc.subjectvalve
dc.subjectTaguchi method
dc.titleImpacts of Valve Angle and Fluid Velocity on Pressure Drop in Pipe Flow
dc.typeResearch Article