Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Uzer, Ayşem" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    A novel acetylcholinesterase inhibition based colorimetric biosensor for the detection of paraoxon ethyl using CUPRAC reagent as chromogenic oxidant
    (Elsevier B.V., 2024) Ayaz, Selen; Ulucay, Sude; Uzer, Ayşem; Dilgin, Yusuf; Apak, Reşat
    A novel colorimetric biosensor for the sensitive and selective detection of an organophosphate pesticide, paraoxon ethyl (POE), was developed based on its inhibitory effect on the acetylcholine esterase (AChE) enzyme. The bis-neocuproine copper (II) complex ([Cu(Nc)2]2+) known as the CUPRAC reagent, was used as a chromogenic oxidant in the AChE inhibition-based biosensors for the first time. To initiate the biosensor, an enzymatic reaction takes place between AChE and its substrate acetylthiocholine (ATCh). Then, enzymatically produced thiocholine (TCh) reacts with the light blue [Cu(Nc)2]2+ complex, resulting in the oxidation of TCh to its disulfide form. On the other hand, [Cu(Nc)2]2+ reduces to a yellow-orange cuprous complex ([Cu(Nc)2]+) which gives maximum absorbance at 450 nm. However, the absorbance of [Cu(Nc)2]+ proportionally decreased with the addition of POE because the inhibition of AChE by the organophosphate pesticide reduced the amount of TCh that would give a colorimetric reaction with the CUPRAC reagent. Based on this strategy, the linear response range of a colorimetric biosensor was found to be between 0.15 and 1.25 μM with a detection limit of 0.045 μM. The fabricated biosensor enabled the selective determination of POE in the presence of some other pesticides and metal ions. The recovery results between 92% and 104% were obtained from water and soil samples spiked with POE, indicating that the determination of POE in real water and soil samples can be performed with this simple, accurate, sensitive, and low-cost colorimetric biosensor.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim