Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Engin, C." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    Electroanalytical Investigation of Paracetamol on Glassy Carbon Electrode by Voltammetry
    (Esg, 2015) Engin, C.; Yilmaz, S.; Saglikoglu, G.; Yagmur, S.; Sadikoglu, M.
    An electroanalytical method was developed for the direct quantitative determination of paracetamol (or acetaminophen) in tablet dosage forms based on its oxidation behavior. The electrochemical oxidation and determination of paracetamol were easily carried out on glassy carbon electrode (GCE) using a variety of voltammetric techniques. The electrochemical measurements were carried out on GCE in various buffer solutions in the pH range from 0.51 to 12.00 by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The dependence of pH on the anodic peak current and peak potential was investigated. Acetate buffer (pH 4.51) was selected for analytical purposes. Scan rate studies were also completed. The diffusion controlled nature of the peak was established. A linear calibration curve for DPV analysis was constructed in the paracetamol concentration range from 4x10(-6) mol/L to 1x10(-4) mol/L. Limit of detection (LOD) and limit of quantification (LOQ) were obtained as 3.69x10(-7) mol/L and 1.23x10(-6) mol/L respectively. Validation of applied voltammetric techniques was checked with recovery studies.
  • [ X ]
    Öğe
    Electroanalytical investigation of paracetamol on glassy carbon electrode by voltammetry
    (Electrochemical Science Group, 2015) Engin, C.; Yilmaz, S.; Saglikoglu, G.; Yagmur, S.; Sadikoglu, M.
    An electroanalytical method was developed for the direct quantitative determination of paracetamol (or acetaminophen) in tablet dosage forms based on its oxidation behavior. The electrochemical oxidation and determination of paracetamol were easily carried out on glassy carbon electrode (GCE) using a variety of voltammetric techniques. The electrochemical measurements were carried out on GCE in various buffer solutions in the pH range from 0.51 to 12.00 by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The dependence of pH on the anodic peak current and peak potential was investigated. Acetate buffer (pH 4.51) was selected for analytical purposes. Scan rate studies were also completed. The diffusion controlled nature of the peak was established. A linear calibration curve for DPV analysis was constructed in the paracetamol concentration range from 4x10-6 mol/L to 1x10-4 mol/L. Limit of detection (LOD) and limit of quantification (LOQ) were obtained as 3.69x10-7 mol/L and 1.23x10-6 mol/L respectively. Validation of applied voltammetric techniques was checked with recovery studies. © 2015 The Authors.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim