dc.identifier.citationBağdat, S., Tokay, F., Demirci, S., Yilmaz, S., & Şahiner, N. (2023). Removal of Cd(II), Co(II), Cr(III), Ni(II), Pb(II) and Zn(II) ions from wastewater using polyethyleneimine (PEI) cryogels. Journal of Environmental Management, 329, 117002. https://doi.org/10.1016/j.jenvman.2022.117002en_US
dc.identifier.issn0301-4797 / 1095-8630
dc.identifier.urihttps://doi.org/10.1016/j.jenvman.2022.117002
dc.identifier.urihttps://hdl.handle.net/20.500.12428/4601
dc.description.abstractThe removal of the target analytes, Cd(II), Co(II), Cr(III), Ni(II), Pb(II), and Zn(II) from contaminated waters was achieved using super porous polyethyleneimine (PEI) cryogels as adsorbent. The optimum values of the sample pH and contact time were determined as 4.0 and 90 min, respectively, for the removal of the analytes. The adsorption capacities of the sorbent were between 19.88 and 24.39 mgg−1 from 10 mL of 50 mgL−1 target metal ion solutions. The sorption kinetics of metal ions were fitted with the pseudo-second-order model. The adsorption isotherms of the target analytes into PEI cryogel were well-fitted to the Langmuir isotherm model as expected from the material homogeneity. The selectivity of the PEI cryogel in the presence of Na+, Ca2+, Mg2+, NO3 −, K+ and Cl− ions even at high concentrations was tested, and the tolerance limits were satisfactory enough, e.g., the adsorption of the target analytes was even not affected in the presence of 2000 mgL−1 Ca2+, K+, Na+, Cl− and 5000 mgL−1 NO3 − ions. The PEI cryogels were successfully utilized in different industrial wastewater samples that were spiked with a known amount of analytes. The removal of the analytes from wastewater samples was in the following ranges 91.94–99.86% for Cd(II), 89.59–99.89% for Co(II), 80.35–99.76% for Cr(III), 92.02–99.84% for Ni(II), 83.28–99.86% for Pb(II), and 82.94–98.24% for Zn(II), respectively. The presented novel removal strategy offers a selective, efficient, and easy application for target metal ions from industrial wastewater samples.en_US
dc.language.isoengen_US
dc.publisherAcademic Pressen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAdsorptionen_US
dc.subjectCryogelen_US
dc.subjectHeavy metal ion removalen_US
dc.subjectMacro porous adsorbenten_US
dc.subjectWastewater treatmenten_US
dc.titleRemoval of Cd(II), Co(II), Cr(III), Ni(II), Pb(II) and Zn(II) ions from wastewater using polyethyleneimine (PEI) cryogelsen_US
dc.typearticleen_US
dc.authorid0000-0001-7083-1481en_US
dc.authorid0000-0003-4607-3523en_US
dc.authorid0000-0003-0120-530Xen_US
dc.relation.ispartofJournal of Environmental Managementen_US
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümüen_US
dc.departmentRektörlük, Rektörlüğe Bağlı Bölümler, Nanobilim ve Teknoloji Araştırma ve Uygulama Merkezien_US
dc.identifier.volume329en_US
dc.institutionauthorDemirci, Şahin
dc.institutionauthorYılmaz, Selehattin
dc.institutionauthorŞahiner, Nurettin
dc.identifier.doi10.1016/j.jenvman.2022.117002en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidHQZ-4087-2023en_US
dc.authorwosid-en_US
dc.authorwosidDVD-0927-2022en_US
dc.authorscopusid56026625600en_US
dc.authorscopusid55964006300en_US
dc.authorscopusid6602001525en_US
dc.identifier.wosqualityQ1en_US
dc.identifier.wosWOS:000906705700001en_US
dc.identifier.scopus2-s2.0-85144046640en_US
dc.identifier.pmidPMID: 36527951en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record