    Biomechanical comparison of tigecycline loaded bone cement with vancomycin and daptomycin loaded bone cements
    (Turkish Assoc Orthopaedics Traumatology, 2020) Muratli, Sedit Kivanc; Karatosun, Vasfi; Uzun, Bora; Gunal, Izge
    Objective: The objectives of this study were 1 to analyze the compressive and tensile mechanical strength characteristics of tigecycline loaded bone cement and 2 to compare them with those of vancomycin and daptomycin loaded bone cements which are used in prosthetic joint infections complicated with resistant microorganisms. Methods: In this study, three experimental groups, which consisted of vancomycin (subgroups containing 1 g, 2 g, and 3 g vancomycin), daptomycin (subgroups containing 0.5 g, 1 g, and 1.5 g daptomycin), and tigecycline (subgroups containing 50 mg, 100 mg, and 150 mg tigecycline) and one control group without antibiotics were used. Using a standardized protocol, all antibiotic loaded bone cements were prepared. For each antibiotic group, including the control group, 10 samples were tested. All samples were biomechanically tested in terms of compressive strength and tensile strength. Results: Compression tests showed that all determined antibiotic concentrations resulted in a significant decrease when compared with the control group (p<0.0011). Vancomycin and daptomycin study groups demonstrated lower tensile strength than the control group (p<0.0011). However, comparison of tensile values of tigecycline study groups with the control group revealed no significant difference (p>0.0011). In addition, all statistically significant results from between groups comparisons revealed higher tensile and compressive mechanical strength values for the tigecycline groups (p<0.0011). Conclusion: Evidence from this study has demonstrated that tigecycline loaded bone cement may have no mechanical disadvantage compared with vancomycin and daptomycin loaded bone cements in terms of mechanical strength when used at defined concentrations.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Comparison of five percutaneous pinning methods for unstable extra-articular distal radius fractures: A mechanical study using sawbones
    (Turkish Joint Diseases Foundation, 2021) Muratlı, Sedit Kıvanç; Uzun, Bora; Çelik, Salih
    Objectives: This study aims to mechanically compare five different extra-focal bi-cortical pin configurations (using two and three pins) employed for fixation of a simulated unstable extra-articular distal radius fracture with dorsal comminution using a sawbone model. Materials and methods: This in vitro mechanical study was conducted between June 2019 and July 2019. A standard fracture model (Arbeitsgemeinschaft für Osteosynthesefragen [AO] type 23-A3.3) was created using a fourth generation composite artificial radius bone. Five groups with two- and three-pin configurations were tested under axial, volar, and dorsal loading with a universal test device. Mean stiffness values were compared statistically. Results: Comparison of stiffness values from axial and volar loading tests between groups in paired comparison showed no statistically significant difference (p=0.194 and p=0.086, respectively). Dorsal loading tests showed statistically significant difference between the groups in pairwise comparison (p=0.002). Three-pin groups (Groups 3, 4, and 5) had higher stiffness values compared to two-pin groups (Groups 1 and 2) in dorsal loading tests (p=0.001). Three-pin configuration test groups with two divergent or convergent pins from the radial styloid performed better compared to both two-pin groups (p=0.01, p=0.002) in dorsal loading tests. Conclusion: Our data demonstrated that the three-pin configuration with two divergent or convergent Kirschner wires from the styloid and a third wire from the dorsal/ulnar cortex had higher stiffness values compared to two-pin configurations in dorsal loading tests. When indicated, we suggest the use of a three-pin construct. Particularly in cases with a risk of volar angulation, we recommend a three-pin configuration with two divergent or convergent bi-cortical Kirschner wires.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim