    Öğe
    Contribution of Rotor-Turbine Ventilator (RTV) on indoor air quality of a cafeteria
    (International Society of Indoor Air Quality and Climate, 2014) Mentese, Sibel; Cotuker, Osman; Selcuk, Burak
    [No abstract available]
  • [ X ]
    Öğe
    INDOOR AIR QUALITY OF A CAFETERIA WITH A ROTOR TURBINE VENTILATOR (RTV) AND CROSS-CORRELATIONS BETWEEN INDOOR AIR POLLUTANTS, OCCUPANCY RATE AND METEOROLOGICAL PARAMETERS
    (Gh Asachi Technical Univ Iasi, 2018) Mentese, Sibel; Cotuker, Osman; Selcuk, Burak
    Indoor air quality (IAQ) improvement potential of rotor turbine ventilator (RTV) was researched by setting up an RTV on the outer part of the chimney of a kitchen, located in a windy city, Canakkale, Turkey. Efficiency of RTV was assessed by preliminary tests, conducted in a three-storey restaurant. After obtaining positive results in terms of airborne bacteria count (TBC) from these tests, long-term measurements were carried out in a cafeteria by air sampling before and after setting up the RTV. In addition to airborne bacteria measurements, concentrations of Total Volatile Organic Compounds (TVOC), Carbon monoxide (CO), Carbon dioxide (CO2), ozone and (fine and coarse) particulate matters (PM) were also measured before and after the RTV installation on the funnel of the cafeteria. Moreover, temperature and relative humidity were measured on-line, and the meteorological parameters were recorded. Furthermore, the number of people in the cafeteria during the air sampling was counted. After the RTV installation, levels of TBC, sum of PM, TVOC, and CO2 clearly decreased, while levels of ozone and CO showed no significant variation during the study. Overall, RTV has potential to improve IAQ, when combined with natural ventilation. In addition to examining the efficiency of RTV, cross-correlations were found among the air pollutants, meteorological/thermal comfort parameters, and the occupancy rate, regardless of the RTV installation. Moreover, statistically significant relationships (p<0.05) were found for number of people in the cafeteria and levels of both CO2 and TBC throughout the entire study.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim