Yazar "Mutlu, İbrahim" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Biomechanical Comparison of Single- and Double-Twist Tension Band, Cancellous Screw, and Single-Screw Tension Band Models in Medial Malleolus Fractures(American Podiatric Med Assoc, 2025) Nusran, Gürdal; Yılmaz, Onur; Mutlu, İbrahim; Kuru, Tolgahan; Erken, H. YenerBackground: Models using a double-twist tension band, two partially threaded cancellous screws, a single-twist tension band, and a single-screw tension band were biomechanically compared for fixation of medial malleolus fractures. Methods: All 72 composite cortical tibial bones used in the study were osteotomy suitable for medial malleolus fracture. They were divided into four groups: double-twist tension band (group 1), two partially threaded cancellous screws (group 2), single-twist tension band (group 3), and single-screw tension band (group 4), with 18 composite tibial bones in each group. Bones in each group were divided into three subgroups and subjected to biomechanical tests by applying force as tension, transverse, and axial loading. Results: In the tension and transverse loading tests, the highest mean stiffness was in groups 1 and 4. Group 4 had statistically significantly higher stiffness values than groups 2 and 3. All of the other groups had statistically significantly higher stiffness values than group 2. A statistically significant difference was found comparing group 4 (with the highest value in the axial loading test) with the other groups. No significant difference was found between groups 1 and 3 in any of the biomechanical tests. Conclusions: Tension band method did not make a difference biomechanically when applied as a double or single twist. Single-screw tension band was found to be the most stable fixation method in tension, transverse, and axial loading tests. We think that the single-screw tension band method is a stable and suitable fixation method and should find more place in current surgical practices.Öğe Comparison of Bicortical Headless Cannulated Screw Fixations, Tension Band Fixations, and Kirschner Wire Fixations of a Jones Fracture A Biomechanical Study(Amer Podiatric Med Assoc, 2024) Yılmaz, Onur; Mutlu, İbrahim; Kuru, Tolgahan; Bilge, Ali; Güngör, Berna; Kızılay, Hasan; Olcar, Hacı; Erken, Hüseyin YenerBackground: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires. Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material. The stiffness and fatigue values were compared between the three fixation groups. Results: In the plantar to dorsal load test, the stiffness values were found to be significantly higher in Group 1 compared to the other groups (P = .034, P = .013). No significant difference was found in the analysis in terms of fatigue values in plantar to dorsal load testing (P = .348, P = .416). No significant difference was found between compression screw and tension band groups in lateral to medial loading test, in terms of stiffness and fatigue values (P = .096, P = .762). However, the stiffness values and fatigue values of these two groups were found to be statistically significantly higher than the Kirschner wire group (P = .003, P = .002, P = .016, P = .023). Conclusions: The result of this study showed that the bicortical fixation of headless compression screw provides a more stable fixation than other fixation methods, especially in plantar to dorsal loading.











