Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Misilli, Umut" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    The effect of curing lights and modes on dentin bond strength of bulk-fill composites applied in different thickness
    (Taylor & Francis Ltd, 2019) Misilli, Tugba; Gonulol, Nihan; Cabadag, Ozge Gizem; Almasifar, Lena; Misilli, Umut
    To investigate shear bond strength (SBS) to dentin of a conventional and three bulk-fill composites applied in different increment thickness and cured by mono- and multi-wave LED LCUs. Two hundred and fifty-two extracted sound human molars were prepared for SBS test. The teeth were divided into four groups according to the resin composites used. Conventional composite: Tetric N-Ceram (control); high-viscosity bulk-fills: Tetric N-Ceram Bulk Fill, X-tra Fil, and SonicFill. Each group was subdivided (n = 7) according to increment thickness (2, 4, and 6 mm) and cured by standard mode of a mono-wave LED or two different modes (standard and xtra power) of a multi-wave LED. The failure mode was stereomicroscopically determined at 40x magnification. Data were analyzed using Three-way ANOVA and further comparisons were assessed by Bonferroni's multiple comparison test. There were no significant differences within X-tra fil and Tetric N-Ceram Bulk Fill groups for any of the variables (p > 0.05). A significant decrease in SBS values with increase of layer thickness was observed for SonicFill and control groups. Also, curing mode had a significant effect on both composites at 6 mm thickness and standard mode of multi-wave LED caused the highest SBS value (p < 0.05). Adhesive failure was the most common fracture pattern especially at 6 mm thickness applications. Based on the results of this study, the bulk-fill composites can be safely applied in one-step with 4 mm increments, although the examined composites performed better at 2 mm thickness. The performance of the composites at 6 mm increment may show differences related to the curing lights and modes.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim