Yazar "Kaya, Bengu Dogu" seçeneğine göre listele
Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Clinical Evaluation of Complications for Single Visit Class III and Class V Restorations at the First Recall Appointment(Marmara Univ, Inst Health Sciences, 2025) Kaya, Bengu Dogu; Korkut, Bora; Ozturk, Ezgi Kizil; Alkan, Elif; Atali, Pinar YilmazObjective: Clinical evaluation of senior students' Class III and Class V restorations at the first recall (control) appointment, regarding revised FDI criteria. Methods: Seventy-six anterior Class III and V restorations were assessed. A nano-ceramic, simplyshade composite (NeoSpectra-ST, Dentsply) was used. Restorative procedures were checked and approved by an experienced (3 years) restorative dentistry instructor. The first recall (control) appointment was scheduled 1 week after the restorations and a restorative instructor re-evaluated the restorations based on the biological, functional, and esthetic aspects of revised FDI criteria. Results: Significantly greater scores were observed for Esthetic criteria compared to Functional and Biological criteria (p<.001). Six failures were detected forform and contour, two for surface luster and texture, two for marginal staining, and two for color match. Onlyfortheform and contour criteria, Class V restorations obtained significantly higher scores than Class III (p=.033). Conclusion: Although anterior composite restorations were approved by an experienced instructor, various irreversible complications were observed at the first recall. Following the restorative procedure, a control appointment shortly is considered mandatory. The highest risk for failure was detected for Esthetic criteria. Class III restorations are considered more prone to failures compared to Class V.Öğe Diastema Closure Following Detection and Removal of Residual Resins After Orthodontic Treatment: Case Report with 1-year follow-up(Marmara Univ, Inst Health Sciences, 2025) Kaya, Bengu Dogu; Atali, Pinar Yilmaz; Sever, Deniz Meltem; Tagtekin, DilekThis case report aimed to determine and remove the residual resins after debonding, to restore the upper lateral teeth with a single shade composite to evaluate with follow-ups. An 18-year-old female patient applied to our clinic with the complaint of the presence of diastemas. Following the sond marking technique, MDP (Smile Lite, Smile Line) and mobile phone (iPhone 11, Apple); DSLR camera (Nikon), macro lens and D-Light caries detection mode (GC) before and after the application of plaque disclosing gel (TriPlaque ID, GC) to detect resin residues on tooth surfaces after bracket removal. The residual resins were removed with finishing and polishing discs (last 3 stages) (OptiDisc, Kerr). One week later, the selective-etch technique, universal adhesive (Gluma Bond Universal, Kulzer), and single shade composite (Charisma Diamond One, Kulzer) were used for diastema closure. The patient was called for follow-up at 3, 6, and 12-months and evaluated FDI criteria. Residual resins were best determined by using a combination of plaque disclosing agent and MDP since the composite used was not a fluorescent light-emitting material. For restorations, FDI 1and 2 scores were observed in the esthetic, functional, and biological evaluations.Öğe Effect of Print Orientation and Thermal Aging on the Flexural Strength of Zirconia-Reinforced Three-Dimensional-Printed Restorative Resin Materials(Mdpi, 2025) Ozden, Yunus Emre; Kaya, Bengu Dogu; Atali, Pinar Yilmaz; Ozer, Fusun; Kayahan, Zeynep OzkurtThis study evaluated the effects of print orientation and thermal aging on the flexural strength (FS) and flexural modulus (FM) of novel permanent three-dimensional (3D)-printed polymethyl methacrylate (PMMA) resins reinforced with nano-zirconia and nano-silica. Bar-shaped specimens (25 x 2 x 2 mm) were fabricated using a digital light processing (DLP) 3D printer (Asiga Max UV, Asiga Inc., Australia) in two orientations (0 degrees and 90 degrees). Specimens underwent three-point bending tests at 24 h and after artificial thermal aging (10,000 and 30,000 cycles) to simulate one and three years of intraoral conditions. Scanning electron microscopy (SEM) was used to analyze fracture patterns. Print orientation did not significantly affect FS or FM (p > 0.05). However, artificial aging significantly reduced FS and FM after 10,000 cycles (p < 0.001), with further deterioration after 30,000 cycles. The micro hybrid resin composite exhibited higher FS than the 3D-printed materials throughout aging. SEM analysis revealed distinct fracture patterns, with 3D-printed resins displaying radial fractures and the micro hybrid composite exhibiting horizontal fractures. These findings indicate that aging plays a more critical role in the long-term mechanical performance of 3D-printed restorative resins than print orientation. This study provides original data on the effects of print orientation and prolonged thermal aging on the mechanical behavior of permanent three-dimensional (3D)-printed dental resins. Furthermore, the comparative evaluation of aging protocols simulating one and three years of intraoral service represents a novel contribution to the existing literature. Further studies are required to optimize the mechanical durability of 3D-printed dental restorations.Öğe The effect of cavity depth on accuracy of intraoral scanners in intra-coronal restorations(Bmc, 2025) Ozden, Yunus Emre; Kaya, Bengu Dogu; Akbal, Cagla; Yilmaz Atali, Pinar; Ozkurt-Kayahan, ZeynepPurpose This study aimed to evaluate the effect of cavity depth on the accuracy of intraoral scanners (IOS) in intra-coronal restorations, focusing on trueness and precision as defined by International Organization for Standardization (ISO) 5725 standards. Materials and methods Three intra-coronal cavity designs with depths of 2.5 mm (n = 10), 5 mm (n = 10), and 7.5 mm (n = 10) were fabricated using 3-Dimentional (3D) printed tooth models. Scans (n = 30) were performed using the Trios 3 intraoral scanner, and accuracy was assessed by comparing scanned models to reference models. Trueness was measured as the root mean square (RMS) deviation, and precision was calculated from the interquartile range of average absolute distances. Statistical analyses were conducted using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction. Results The accuracy of the IOS was significantly lower at a cavity depth of 7.5 mm compared to 5 mm and 2.5 mm (p < 0.05). RMS values were highest for the 7.5 mm depth, while the lowest precision was observed at this depth. Conclusion Cavity depth significantly affects the accuracy of IOS in intra-coronal restorations, with deeper cavities resulting in reduced accuracy. This highlights the importance of considering cavity depth when planning IOS workflows. This study shows that scanning accuracy decreases when the distance between the cavity floor and the cusp tip exceeds 5 mm. Elevating the cavity floor with direct methods may help improve scanning accuracy and enhance restoration outcomes.











