Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Kömür, Bariş" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    The relationship between tear osmolarity, ocular surface disease index© and other tear function tests
    (Turkiye Klinikleri, 2013) Taşkiran Çömez, Arzu; Kömür, Bariş; Şanal, Elif; Tufan, Hasan Ali
    Objective: To evaluate the relationship between tear osmolarity, Ocular Surface Disease Index (OSDI© Allergan Inc., Irvine, Calif), Schirmer test and tear break-up time (TBUT). Material and Methods: After performing Ocular Surface Disease Index (OSDI©) survey, tear osmolarity testing with TearLab osmolarity system, Schirmer test without anesthesia and TBUT measurement were performed in 40 patients with dry eye syndrome diagnosis and 39 healthy subjects. Student t-test and Spearman's rho correlation analysis are used for statistical evaluation. Results: The mean tear osmolarity was 307±19.2 mOsm/l in group A, while it was 292.9±13.9 mOsm/l in group B. Schirmer test results were in normal ranges in both groups (13.4±7.5 mm in group A, and 17.4±8.5 mm in group B). TBUT was lower in group A, and the difference between two groups was statistically significant. OSDI© scoring was 43.9±20.4 in group A, while it was 8.56± 5.2 in group B and the difference was statistically significant. The sensitivity and spesificity of tear osmolarity for threshold value 305 mOsm/l were found to be 76.9 % and 80%, for TBUT for 10 seconds were 94.7% and 71.8%; for OSDI© score >15 were 79.5% and 70% and for Schirmer's test for 10 mm were 35.9% and 80%. Conclusion: Of all tests, TBUT, tear osmolarity and OSDI© are found to be successful in discriminating dry eye patients from healthy participants. The specificity and the sensitivity of the commonly used Schirmer test are found to be low. © 2013 by Türkiye Klinikleri.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim