    A label-free dual immunosensor for the simultaneous electrochemical determination of CA125 and HE4 biomarkers for the early diagnosis of ovarian cancer
    (Springer Science and Business Media Deutschland GmbH, 2023) Bilgi Kamaç, Melike; Altun, Muhammed; Yılmaz, Merve; Sezgintürk, Mustafa Kemal
    The blood levels of cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are measured in the diagnosis and progression monitoring of ovarian cancer (OC), and the Risk of Ovarian Malignancy Algorithm (ROMA) score% values are calculated for cancer risk assessment. For the first time, disposable dual screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles were used to fabricate label-free electrochemical dual CA125-HE4 immunosensors for the sensitive, fast, and practical simultaneous determination of CA125 and HE4. DPV and SWV methods were used to simultaneously determine antigens in two different linear ranges (1–100 pg mL−1 and 1–50 ng mL−1). High sensitivity, low LOD, and LOQ were obtained for two linear ranges with a correlation coefficient above 0.99. The application stability of the dual CA125-HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. The dual immunosensors exhibited high selectivity in eight different antigen mixtures. The reusability of the dual immunosensors has been tested up to 9 cycles. ROMA score% values for pre-menopausal and post-menopausal status were calculated using the concentration of CA125 and HE4 in the blood serum and assessing OC risk. The disposable dual immunosensors can be used in point-of-care tests for rapid and practical simultaneous determination of CA125 and HE4 with high selectivity, sensitivity, and repeatability.
  • Yükleniyor...
    Küçük Resim
    Öğe
    Point-of-care testing: a disposable label-free electrochemical CA125 and HE4 immunosensors for early detection of ovarian cancer
    (Springer, 2023) Bilgi Kamaç, Melike; Altun, Muhammed; Yılmaz, Merve; Yılmaz Aktan, Ayla; Aktan, Soner; Sezgintürk, Mustafa Kemal
    Cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are critical biomarkers for ovarian cancer diagnosis and progression monitoring; therefore, sensitive determination of their levels in body fluids is crucial. In recent study, label-free CA125 and HE4 immunosensors were prepared using disposable screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles for the sensitive, fast, and practical determination of CA125 and HE4. Differential pulse voltammetry, square wave voltammetry, and electrochemical impedance spectroscopy methods were used for the electrochemical determination of antigens in four different linear ranges (1-100 pg mL− 1, 0.01-10 ng mL− 1, 10–50 ng mL− 1, and 50–500 ng mL− 1). High sensitivity, low limit of detection, and limit of quantification were obtained for each linear range with a correlation coefficient above 0.99. The application stability of CA125 and HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. Immunosensors showed high selectivity in nine different antigen mixtures. The reusability of the immunosensors has been tested up to 9 cycles. The Risk of Ovarian Malignancy Algorithm score% values were calculated using the concentration of CA125 and HE4 in the blood serum and evaluated in terms of ovarian cancer risk. For the point-of-care testing, CA125 and HE4 levels at pg mL− 1 concentration were measured in blood serum samples using the developed immunosensors and a hand-held electrochemical reader in approximately 20–30 s, and high recoveries were obtained. These disposable label-free immunosensors are user-friendly and can be used in point-of-care tests for rapid and practical detection of CA125 and HE4 with high selectivity, sensitivity, and repeatability.

| Çanakkale Onsekiz Mart Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Çanakkale Onsekiz Mart Üniversitesi, Çanakkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim