Advanced Search

Show simple item record

dc.contributor.authorEmir, Gamze
dc.contributor.authorKarakaya, Serkan
dc.contributor.authorAyaz, Selen
dc.contributor.authorDilgin, Didem Giray
dc.contributor.authorDilgin, Yusuf
dc.date.accessioned2024-12-18T06:32:33Z
dc.date.available2024-12-18T06:32:33Z
dc.date.issued2021en_US
dc.identifier.citationEmir, G., Karakaya, S., Ayaz, S., Dilgin, D. G., & Dilgin, Y. (2021). Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4–NiO and CuO–Co3O4) modified pencil graphite electrodes. Monatshefte Für Chemie - Chemical Monthly, 152(12), 1491–1503. https://doi.org/10.1007/s00706-021-02861-0en_US
dc.identifier.issn0026-9247 / 1434-4475
dc.identifier.urihttps://doi.org/10.1007/s00706-021-02861-0
dc.identifier.urihttps://hdl.handle.net/20.500.12428/6750
dc.description.abstractIn this work, a highly efficient performance of bimetallic thin films as their oxide forms (Co3O4-NiO and CuO-Co3O4) modified on pencil graphite electrodes (PGEs) was presented for electrocatalytic oxidation of formaldehyde. In addition, a sensitive and selective amperometric determination of formaldehyde in flow injection analysis system have been first performed using binary transition metal oxides modified PGEs. Co3O4-NiO and CuO-Co3O4 films were electrochemically deposited on the PGE surface using cyclic voltammetric procedures. The recorded cyclic voltammograms in the presence of formaldehyde in 0.10 M NaOH containing 0.10 M KCl showed that the prepared binary transition metal oxides modified PGEs exhibited a higher electrocatalytic activity than single metal oxide thin films modified PGEs towards oxidation of formaldehyde. The linear responses based on electrocatalytic oxidation of formaldehyde were determined as 2.5-5000 mu M and 0.25-1000 mu M for Co3O4-NiO/PGE and CuO-Co3O4/PGE, respectively. Moreover, limit of detections and sensitivities were estimated as 0.73 mu M and 81.8 mu A mM(-1) cm(-2) and 0.09 mu M and 166 mu A mM(-1) cm(-2) for Co3O4-NiO/PGE and CuO-Co3O4/PGE, respectively. The results from real sample studies proved that the fabricated FI-amperometric sensors enable high applicability towards determination of formaldehyde in real water samples.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrochemistryen_US
dc.subjectFlow injection analysisen_US
dc.subjectFormaldehydeen_US
dc.subjectPencil graphite electrodeen_US
dc.subjectSensoren_US
dc.subjectVoltammetryen_US
dc.titleElectrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4-NiO and CuO-Co3O4) modified pencil graphite electrodesen_US
dc.typearticleen_US
dc.authorid0000-0002-3976-2243en_US
dc.authorid0000-0002-6401-3295en_US
dc.authorid0000-0003-0320-3551en_US
dc.authorid0000-0002-3487-3470en_US
dc.authorid0000-0002-2980-6871en_US
dc.relation.ispartofMonatshefte fur Chemieen_US
dc.departmentFakülteler, Eğitim Fakültesi, Matematik ve Fen Bilimleri Eğitimi Bölümüen_US
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümüen_US
dc.identifier.volume152en_US
dc.identifier.issue12en_US
dc.identifier.startpage1491en_US
dc.identifier.endpage1503en_US
dc.institutionauthorEmir, Gamze
dc.institutionauthorKarakaya, Serkan
dc.institutionauthorAyaz, Selen
dc.institutionauthorDilgin, Didem Giray
dc.institutionauthorDilgin, Yusuf
dc.identifier.doi10.1007/s00706-021-02861-0en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosid-en_US
dc.authorwosidABD-2343-2020en_US
dc.authorwosid-en_US
dc.authorwosidGFN-2153-2022en_US
dc.authorwosidW-4565-2017en_US
dc.authorscopusid57196192033en_US
dc.authorscopusid56374132900en_US
dc.authorscopusid57197830377en_US
dc.authorscopusid36547673600en_US
dc.authorscopusid6507953466en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:000709737200001en_US
dc.identifier.scopus2-s2.0-85117488482en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record