Fabrication of Electrochemical Immunosensor for Detection of Interleukin 8 Biomarker via Layer-by-layer Self-assembly Process on Cost-effective Fluorine Tin Oxide Electrode
Citation
Aydın, E. B., & Sezgintürk, M. K. (2021). Fabrication of Electrochemical Immunosensor for Detection of Interleukin 8 Biomarker via Layer‐by‐layer Self‐assembly Process on Cost‐effective Fluorine Tin Oxide Electrode. Electroanalysis, 33(6), 1596–1605. https://doi.org/10.1002/elan.202060603 Abstract
A highly sensitive impedimetric immunosensor for the determination of interleukin 8 (IL 8) cancer biomarker was fabricated via simple fabrication process. A silane agent with isocyanate groups, 3-(triethoxysilyl)propyl isocyanate (IPTES), were utilized for binding of IL 8 antigen specific antibodies and self-assembled on the fluorine tin oxide (FTO) substrate with a standard silanization chemistry. Under optimum experimental conditions, the designed immunosensor had a wide linear detection range of 0.02-4 pg/mL, a low limit of detection of 11.9 fg/mL and a high sensitivity of 4.42 k omega pg(-1) mL cm(-2). The designed biosensor displayed high reproducibility and repeatability, good selectivity against interference biomarkers.