Advanced Search

Show simple item record

dc.contributor.authorBilici, Ali
dc.contributor.authorDenizhan, Nuray
dc.contributor.authorEmre, Deniz
dc.contributor.authorYılmaz, Selehattin
dc.contributor.authorSoylukan, Caner
dc.contributor.authorAlgi, Fatih
dc.date.accessioned2024-12-18T10:48:55Z
dc.date.available2024-12-18T10:48:55Z
dc.date.issued2021en_US
dc.identifier.citationBilici, A., Denizhan, N., Emre, D., Soylukan, C., Algı, F., & Yılmaz, S. (2021). Fabrication of PAMP/Au and GO/PAMP/Au nanosensors for electrochemical detection of paracetamol in pharmaceutical preparations. Monatshefte Für Chemie - Chemical Monthly, 152(12), 1539–1552. https://doi.org/10.1007/s00706-021-02866-9en_US
dc.identifier.issn0026-9247 / 1434-4475
dc.identifier.urihttps://doi.org/10.1007/s00706-021-02866-9
dc.identifier.urihttps://hdl.handle.net/20.500.12428/6752
dc.description.abstractThis paper reports on the modification of Pencil Graphite Electrode (PGE) surface with the poly(2-amino-4-methylphenol)/gold (PAMP/Au) and graphene oxide/poly(2-amino-4-methylphenol)/gold (GO/PAMP/Au) nanocomposites, in two steps. The first step is based on the one-pot preparation of composites by template-free chemical oxidation process. In the second step, composites are deposited at PGE surface by electro-oxidation process. Both nanocomposites and modified PGE surfaces are characterized by X-Ray Diffraction method (XRD), Scanning Electron Microscopy (SEM), EDAX, and CV analyses. The electrochemical performances of modified electrodes (abbreviated as PAMP/Au-PGE and GO/PAMP/Au-PGE) were investigated. The limit of detection values for PGE, PAMP/Au-PGE, and GO/PAMP/Au-PGE were found to be 2.74 × 10–6, 5.29 × 10–7, and 2.91 × 10–8 mol/dm3, respectively. The limit of quantification values were determined as 9.14 × 10–6, 1.76 × 10–6, and 9.69 × 10–8 mol/dm3 for PGE, PAMP/Au-PGE, and GO/PAMP/Au-PGE, respectively.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrochemistryen_US
dc.subjectGraphene oxideen_US
dc.subjectPencil graphite electrodeen_US
dc.subjectPoly(2-hydroxy-5-methylaniline)en_US
dc.subjectPolymerizationen_US
dc.subjectSensorsen_US
dc.titleFabrication of PAMP/Au and GO/PAMP/Au nanosensors for electrochemical detection of paracetamol in pharmaceutical preparationsen_US
dc.typearticleen_US
dc.authorid0000-0002-1377-5580en_US
dc.authorid0000-0003-3067-3954en_US
dc.authorid0000-0003-0493-8154en_US
dc.authorid0000-0003-4607-3523en_US
dc.relation.ispartofMonatshefte fur Chemieen_US
dc.departmentFakülteler, Fen Fakültesi, Kimya Bölümüen_US
dc.departmentMeslek Yüksekokulları, Sağlık Hizmetleri Meslek Yüksekokulu, Eczane Hizmetleri Bölümüen_US
dc.identifier.volume152en_US
dc.identifier.issue12en_US
dc.identifier.startpage1539en_US
dc.identifier.endpage1552en_US
dc.institutionauthorBilici, Ali
dc.institutionauthorDenizhan, Nuray
dc.institutionauthorEmre, Deniz
dc.institutionauthorYılmaz, Selehattin
dc.identifier.doi10.1007/s00706-021-02866-9en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidEPR-7274-2022en_US
dc.authorwosid-en_US
dc.authorwosidAAD-1940-2021en_US
dc.authorwosidITI-9573-2023en_US
dc.authorscopusid13405405500en_US
dc.authorscopusid57330659200en_US
dc.authorscopusid16021622500en_US
dc.authorscopusid55964006300en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:000717903200001en_US
dc.identifier.scopus2-s2.0-85118957175en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record