dc.contributor.author | Emir, Gamze | |
dc.contributor.author | Karakaya, Serkan | |
dc.contributor.author | Ayaz, Selen | |
dc.contributor.author | Dilgin, Didem Giray | |
dc.contributor.author | Dilgin, Yusuf | |
dc.date.accessioned | 2024-12-18T06:32:33Z | |
dc.date.available | 2024-12-18T06:32:33Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.citation | Emir, G., Karakaya, S., Ayaz, S., Dilgin, D. G., & Dilgin, Y. (2021). Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4–NiO and CuO–Co3O4) modified pencil graphite electrodes. Monatshefte Für Chemie - Chemical Monthly, 152(12), 1491–1503. https://doi.org/10.1007/s00706-021-02861-0 | en_US |
dc.identifier.issn | 0026-9247 / 1434-4475 | |
dc.identifier.uri | https://doi.org/10.1007/s00706-021-02861-0 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/6750 | |
dc.description.abstract | In this work, a highly efficient performance of bimetallic thin films as their oxide forms (Co3O4-NiO and CuO-Co3O4) modified on pencil graphite electrodes (PGEs) was presented for electrocatalytic oxidation of formaldehyde. In addition, a sensitive and selective amperometric determination of formaldehyde in flow injection analysis system have been first performed using binary transition metal oxides modified PGEs. Co3O4-NiO and CuO-Co3O4 films were electrochemically deposited on the PGE surface using cyclic voltammetric procedures. The recorded cyclic voltammograms in the presence of formaldehyde in 0.10 M NaOH containing 0.10 M KCl showed that the prepared binary transition metal oxides modified PGEs exhibited a higher electrocatalytic activity than single metal oxide thin films modified PGEs towards oxidation of formaldehyde. The linear responses based on electrocatalytic oxidation of formaldehyde were determined as 2.5-5000 mu M and 0.25-1000 mu M for Co3O4-NiO/PGE and CuO-Co3O4/PGE, respectively. Moreover, limit of detections and sensitivities were estimated as 0.73 mu M and 81.8 mu A mM(-1) cm(-2) and 0.09 mu M and 166 mu A mM(-1) cm(-2) for Co3O4-NiO/PGE and CuO-Co3O4/PGE, respectively. The results from real sample studies proved that the fabricated FI-amperometric sensors enable high applicability towards determination of formaldehyde in real water samples. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Springer | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Electrochemistry | en_US |
dc.subject | Flow injection analysis | en_US |
dc.subject | Formaldehyde | en_US |
dc.subject | Pencil graphite electrode | en_US |
dc.subject | Sensor | en_US |
dc.subject | Voltammetry | en_US |
dc.title | Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4-NiO and CuO-Co3O4) modified pencil graphite electrodes | en_US |
dc.type | article | en_US |
dc.authorid | 0000-0002-3976-2243 | en_US |
dc.authorid | 0000-0002-6401-3295 | en_US |
dc.authorid | 0000-0003-0320-3551 | en_US |
dc.authorid | 0000-0002-3487-3470 | en_US |
dc.authorid | 0000-0002-2980-6871 | en_US |
dc.relation.ispartof | Monatshefte fur Chemie | en_US |
dc.department | Fakülteler, Eğitim Fakültesi, Matematik ve Fen Bilimleri Eğitimi Bölümü | en_US |
dc.department | Fakülteler, Fen Fakültesi, Kimya Bölümü | en_US |
dc.identifier.volume | 152 | en_US |
dc.identifier.issue | 12 | en_US |
dc.identifier.startpage | 1491 | en_US |
dc.identifier.endpage | 1503 | en_US |
dc.institutionauthor | Emir, Gamze | |
dc.institutionauthor | Karakaya, Serkan | |
dc.institutionauthor | Ayaz, Selen | |
dc.institutionauthor | Dilgin, Didem Giray | |
dc.institutionauthor | Dilgin, Yusuf | |
dc.identifier.doi | 10.1007/s00706-021-02861-0 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorwosid | - | en_US |
dc.authorwosid | ABD-2343-2020 | en_US |
dc.authorwosid | - | en_US |
dc.authorwosid | GFN-2153-2022 | en_US |
dc.authorwosid | W-4565-2017 | en_US |
dc.authorscopusid | 57196192033 | en_US |
dc.authorscopusid | 56374132900 | en_US |
dc.authorscopusid | 57197830377 | en_US |
dc.authorscopusid | 36547673600 | en_US |
dc.authorscopusid | 6507953466 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.identifier.wos | WOS:000709737200001 | en_US |
dc.identifier.scopus | 2-s2.0-85117488482 | en_US |