dc.contributor.author | Yaman, Burcu | |
dc.contributor.author | Zaman, Buse Tuğba | |
dc.contributor.author | Bakırdere, Sezgin | |
dc.contributor.author | Dilgin, Yusuf | |
dc.date.accessioned | 2024-12-09T13:15:24Z | |
dc.date.available | 2024-12-09T13:15:24Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.citation | Yaman, B., Zaman, B. T., Sezgin Bakırdere, & Yusuf Dilgin. (2021). Sensitive, Accurate and Selective Determination of Cd(II) Using Anodic Stripping Voltammetry with in‐situ Hg‐Bi Film Modified Pencil Graphite Electrode After Magnetic Dispersive Solid Phase Microextraction. Electroanalysis, 33(10), 2161–2168. https://doi.org/10.1002/elan.202100228 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.uri | https://doi.org/10.1002/elan.202100228 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12428/6717 | |
dc.description.abstract | This paper describes a novel approach to detect Cd(II) using the combination of the differential pulse anodic stripping voltammetry and magnetic nanoparticle based dispersive solid phase microextraction as an efficient, green and accurate method. Currents of Cd(II) increased linearly in the range from 75 to 2000 ng L−1 Cd(II) with a detection limit of 21.6 ng L−1. The RSD values of 2.6 and 6.0 % for 1.00 and 0.10 μg L−1 respectively showed that proposed method has an acceptable repeatability. Recovery values between 92.3 and 98.6 % showed that this approach can be successfully used for determination of Cd(II) in water samples. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | John Wiley and Sons Inc | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cadmium | en_US |
dc.subject | Dispersive solid phase microextraction | en_US |
dc.subject | Stripping voltammetry | en_US |
dc.subject | Magnetic nanoparticles | en_US |
dc.subject | Graphite pencilelectrode | en_US |
dc.title | Sensitive, Accurate and Selective Determination of Cd(II) Using Anodic Stripping Voltammetry With In-situ Hg-Bi Film Modified Pencil Graphite Electrode After Magnetic Dispersive Solid Phase Microextraction | en_US |
dc.type | article | en_US |
dc.authorid | 0000-0002-0836-4891 | en_US |
dc.authorid | 0000-0002-2980-6871 | en_US |
dc.relation.ispartof | Electroanalysis | en_US |
dc.department | Fakülteler, Fen Fakültesi, Kimya Bölümü | en_US |
dc.identifier.volume | 33 | en_US |
dc.identifier.issue | 10 | en_US |
dc.identifier.startpage | 2161 | en_US |
dc.identifier.endpage | 2168 | en_US |
dc.institutionauthor | Yaman, Burcu | |
dc.institutionauthor | Dilgin, Yusuf | |
dc.identifier.doi | 10.1002/elan.202100228 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.authorwosid | - | en_US |
dc.authorwosid | W-4565-2017 | en_US |
dc.authorscopusid | 57225174869 | en_US |
dc.authorscopusid | 6507953466 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.identifier.wos | WOS:000671454500001 | en_US |
dc.identifier.scopus | 2-s2.0-85109401841 | en_US |