Demirbilek, EsraSaglikoglu, GulsenYilmaz, Selehattin2025-01-272025-01-2720151452-3981https://hdl.handle.net/20.500.12428/27121Isoniazid is a tuberculostatic agent effective active compound. A glassy carbon electrode (GCE) was modified with an electropolymerized film of p-aminobenzene sulfonic acid (p-ABSA) in phosphate buffer solution (PBS). The electrochemical properties of isoniazid on modified electrode were studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The polymer film-modified electrode was used to electrochemically detect isoniazid. The polymer film had excellent electrocatalytic activity for the oxidation of isoniazid. A linear calibration curve for DPV analysis was constructed in the isoniazid concentration range 2x10(-5) - 1x10(-4) mol L-1. Limit of detection (LOD) and limit of quantification (LOQ) were obtained as 3.05x10(-6) and 1.01x10(-5) mol L-1 respectively. Isoniazid was determined in tablet dosage form. The proposed method exhibits good recovery and reproducibility. The mechanisms of electropolymerization were also suggested.eninfo:eu-repo/semantics/closedAccessp-Aminobenzene sulfonic acidModified-glassy carbon electrodeElectropolymerizationElectrocatalytic-oxidationDetermination of isoniazidElectrochemical Investigation of Isoniazid on Poly (p-Aminobenzene Sulfonic Acid) Film Modified Glassy Carbon ElectrodeArticle10544284438Q3WOS:000354782200063