Advanced Search

Show simple item record

dc.contributor.advisorSezgintürk, Mustafa Kemal
dc.contributor.authorŞentürk, Şeyma
dc.date.accessioned2023-12-11T19:56:52Z
dc.date.available2023-12-11T19:56:52Z
dc.date.issued2023
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=G_oJ1rKE4SgJUkomyAKpRzPblDkAIQepM-tPw8D24880wXEx6i27Dg5Js6NG_a8j
dc.identifier.urihttps://hdl.handle.net/20.500.12428/4695
dc.description.abstractBöbrek Hasarı Molekülü-1 (KIM-1), bir tip I transmembran glikoproteinidir ve akut böbrek hasarı durumunda idrarda seviyesinin değişkenlik gösterdiği için böbrek hasarını saptamak adına potansiyel bir biyomarkerdır. Tez kapsamında, KIM-1 biyomarkerının tayinine yönelik elektrokimyasal bir immünosensör tasarlanmıştır. Geliştirilen biyosensör sistemi için çalışma elektrodu olarak Quartz Tuning Fork (QTF) kullanılmıştır. Altın uçlu QTF elektrodu yüzeyi, SAM tabakası oluşturmak için 11-Merkaptoundekanoik asit (11-MUA) ile modifiye edilmiştir. Biyosensör için, tasarımında kullanılan parametreleri üzerinde detaylı optimizasyon çalışmaları, ardından karakterizasyon çalışmaları ve gerçek idrarda uygulanabilirlik çalışmaları yapılmıştır. Bu çalışmalar, elektrokimyasal empedans spektroskopisi (EIS) ve döngüsel voltametri (CV) yöntemleri ile analiz edilmiştir. Geliştirilen immünosensörün elektrot yüzeyindeki morfolojik değişimleri incelemek için Atomik Kuvvet Mikroskobu (AFM) ve Taramalı Elektron Mikroskobu (SEM) cihazlarında görüntüler alınmıştır. Geliştirilen biyosensör sistemi, geniş bir tayin aralığını (0,05-250 fg/mL) algılamak için yüksek kapasiteye sahiptir.en_US
dc.description.abstractKidney Injury Molecule-1 (KIM-1) is a type I transmembrane glycoprotein and is a potential biomarker for detecting kidney injury as its level in the urine varies in acute kidney injury. Within the scope of the thesis, an electrochemical immunosensor was designed for the determination of the KIM-1 biomarker. Quartz Tuning Fork (QTF) was used as the working electrode for the developed biosensor system. The gold-tipped QTF electrode surface was modified with 11-Mercaptoundecanoic acid (11-MUA) to form the SAM layer. For the biosensor, detailed optimization studies were carried out on the parameters used in its design, followed by characterization studies and applicability studies in real urine. These studies were analyzed by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) methods. Images were taken in Atomic Force Microscope (AFM) and Scanning Electron Microscope (SEM) devices to examine the morphological changes on the electrode surface of the developed immunosensor. The developed biosensor system has a high capacity to detect a wide detection range (0.05-250 fg/mL).en_US
dc.language.isoturen_US
dc.publisherÇanakkale Onsekiz Mart Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiyomühendisliken_US
dc.subjectBioengineeringen_US
dc.titleAkut böbrek hasarının potansiyel biyomarkerlarından KIM-1 tayini için elektrokimyasal immünosensör sisteminin geliştirilmesien_US
dc.title.alternativeDevelopment of electrochemical immunosensor system for the detection of KIM-1, a potential biomarker of acute kidney injuryen_US
dc.typemasterThesisen_US
dc.departmentÇOMÜ, Enstitüler, Lisansüstü Eğitim Enstitüsü, Biyomühendislik ve Malzeme Mühendisliği Ana Bilim Dalıen_US
dc.identifier.startpage1en_US
dc.identifier.endpage65en_US
dc.institutionauthorŞentürk, Şeyma
dc.relation.publicationcategoryTezen_US
dc.identifier.yoktezid795129en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record