Advanced Search

Show simple item record

dc.contributor.authorBilgi Kamaç, Melike
dc.contributor.authorAltun, Muhammed
dc.contributor.authorYılmaz, Merve
dc.contributor.authorYılmaz Aktan, Ayla
dc.contributor.authorAktan, Soner
dc.contributor.authorSezgintürk, Mustafa Kemal
dc.date.accessioned2023-09-09T12:41:06Z
dc.date.available2023-09-09T12:41:06Z
dc.date.issued2023en_US
dc.identifier.citationKamaç, M. B., Altun, M., Yılmaz, M., Aktan, A. Y., Aktan, S., & Sezgintürk, M. K. (2023). Point-of-care testing: a disposable label-free electrochemical CA125 and HE4 immunosensors for early detection of ovarian cancer. Biomedical Microdevices, 25(2), 1–15. https://doi.org/10.1007/s10544-023-00659-xen_US
dc.identifier.issn1387-2176 / 1572-8781
dc.identifier.urihttps://doi.org/10.1007/s10544-023-00659-x
dc.identifier.urihttps://hdl.handle.net/20.500.12428/4556
dc.description.abstractCancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are critical biomarkers for ovarian cancer diagnosis and progression monitoring; therefore, sensitive determination of their levels in body fluids is crucial. In recent study, label-free CA125 and HE4 immunosensors were prepared using disposable screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles for the sensitive, fast, and practical determination of CA125 and HE4. Differential pulse voltammetry, square wave voltammetry, and electrochemical impedance spectroscopy methods were used for the electrochemical determination of antigens in four different linear ranges (1-100 pg mL− 1, 0.01-10 ng mL− 1, 10–50 ng mL− 1, and 50–500 ng mL− 1). High sensitivity, low limit of detection, and limit of quantification were obtained for each linear range with a correlation coefficient above 0.99. The application stability of CA125 and HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. Immunosensors showed high selectivity in nine different antigen mixtures. The reusability of the immunosensors has been tested up to 9 cycles. The Risk of Ovarian Malignancy Algorithm score% values were calculated using the concentration of CA125 and HE4 in the blood serum and evaluated in terms of ovarian cancer risk. For the point-of-care testing, CA125 and HE4 levels at pg mL− 1 concentration were measured in blood serum samples using the developed immunosensors and a hand-held electrochemical reader in approximately 20–30 s, and high recoveries were obtained. These disposable label-free immunosensors are user-friendly and can be used in point-of-care tests for rapid and practical detection of CA125 and HE4 with high selectivity, sensitivity, and repeatability.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCA125en_US
dc.subjectElectrochemical immunosensorsen_US
dc.subjectHE4en_US
dc.subjectOvarian canceren_US
dc.subjectPoint-of-care testingen_US
dc.titlePoint-of-care testing: a disposable label-free electrochemical CA125 and HE4 immunosensors for early detection of ovarian canceren_US
dc.typearticleen_US
dc.authorid0000-0003-3042-1087en_US
dc.relation.ispartofBiomedical Microdevicesen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomühendislik Bölümüen_US
dc.identifier.volume25en_US
dc.identifier.issue2en_US
dc.institutionauthorSezgintürk, Mustafa Kemal
dc.identifier.doi10.1007/s10544-023-00659-xen_US
dc.relation.ecinfo:eu-repo/grantAgreement/TUBITAK/SOBAG/118R030
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidAAY-1439-2021en_US
dc.authorscopusid6506764918en_US
dc.identifier.wosqualityQ3en_US
dc.identifier.wosWOS:000981582700001en_US
dc.identifier.scopus2-s2.0-85157961203en_US
dc.identifier.pmidPMID: 37361883en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record