Advanced Search

Show simple item record

dc.contributor.authorAydın, Elif Burcu
dc.contributor.authorAydın, Muhammet
dc.contributor.authorSezgintürk, Mustafa Kemal
dc.date.accessioned2023-08-01T08:07:09Z
dc.date.available2023-08-01T08:07:09Z
dc.date.issued2023en_US
dc.identifier.citationAydın, E. B., Aydın, M., & Sezgintürk, M. K. (2023). A Simple and Low‐Cost Electrochemical Immunosensor for Ultrasensitive Determination of Calreticulin Biomarker in Human Serum. Macromolecular Bioscience, 23(1). https://doi.org/10.1002/mabi.202200390en_US
dc.identifier.issn1616-5187 / 1616-5195
dc.identifier.urihttps://doi.org/10.1002/mabi.202200390
dc.identifier.urihttps://hdl.handle.net/20.500.12428/4473
dc.description.abstractAn early on time detection of breast cancer significantly affects the treatment process and outcome. Herein, a new label-free impedimetric biosensor is developed to determine the lowest change in the level of calreticulin (CALR), which is a new biomarker of breast carcinoma. The proposed immunosensor is fabricated by using reduced graphene oxide/amino substituted polypyrrole polymer (rGO-PPyNH2) nanocomposite modified disposable electrode. The anti-CALR antibodies are first attached on the rGO-PPyNH2 nanocomposite coated electrode through glutaraldehyde crosslinking; the CALR antigens are then immobilized with the addition of CALR antigens to form an immunocomplex on the sensing surface. This immunocomplex induces considerably larger interfacial electron transport resistance (Rct). The variation in the Rct has a linear relationship with CALR level in the detection range of 0.025 to 75 pg mL−1, with a detection limit of 10.4 fg mL−1. The suggested biosensor shows high selectivity to CALR, good storage stability (at least 5 weeks) and suitable reproducibility results as shown in quality control chart. The designed immunosensor is utilized to analyze CALR levels in human sera with satisfying results. This immunosensor provides a novel way for the clinical determination of CALR and other cancer biological markers.en_US
dc.language.isoengen_US
dc.publisherJohn Wiley and Sons Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCalreticulinen_US
dc.subjectImpedimetric immunosensoren_US
dc.subjectReagentless analysisen_US
dc.subjectReduced graphene oxideen_US
dc.titleA Simple and Low-Cost Electrochemical Immunosensor for Ultrasensitive Determination of Calreticulin Biomarker in Human Serumen_US
dc.typearticleen_US
dc.authorid0000-0003-3042-1087en_US
dc.relation.ispartofMacromolecular Bioscienceen_US
dc.departmentFakülteler, Mühendislik Fakültesi, Biyomühendislik Bölümüen_US
dc.identifier.volume23en_US
dc.identifier.issue1en_US
dc.institutionauthorSezgintürk, Mustafa Kemal
dc.identifier.doi10.1002/mabi.202200390en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidAAY-1439-2021en_US
dc.authorscopusid6506764918en_US
dc.identifier.wosqualityQ2en_US
dc.identifier.wosWOS:000893339200001en_US
dc.identifier.scopus2-s2.0-85143974323en_US
dc.identifier.pmidPMID: 36419333en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record